  • Adding storage Pure Storage FlashArray X50 fails with firmware
    6.1.5.
    
    Probe log shows:
    Error Apr 16, 2021 08:50:49.648
    HWN025032E Job failed during post processing of collected data
    from the data source.
    Error Apr 16, 2021 08:50:53.461
    HWNEP0135E External process failed with error code 99.
    Error
    Apr 16, 2021 08:50:53.462 HWN021503E The action cannot be
    completed
    Information Apr 16, 2021 08:50:53.464 HWN021709I
    Collection for storage system Pure Storage FlashArray FA-X50
    completed.
    Error Apr 16, 2021 08:50:53.498 BTADS0102E The probe
    with the run ID 1100 completed with
    errors.
    
    process_pure_mx.log shows:
    2021-04-16 01:55:27.102 -
    INFO - HWN6010I Task Storing_Host_Connection_Records completed
    successfully
    2021-04-16 01:55:27.264 - INFO - HWN6010I Task
    Storing_Port_Records completed successfully
    2021-04-16
    01:55:27.264 - ERROR - Error processing data files.
    Exiting...
    2021-04-16 01:55:27.264 - DEBUG - Writing status
    file...
    2021-04-16 01:55:27.264 - DEBUG - Exit code:
    99
    2021-04-16 01:55:27.265 - DEBUG - Traceback (most recent
    call last):
     File "vsi_thirdparty/MainLauncher.py", line 357,
    in run_reporter
     File "Reporter.py", line 95, in start
     File
    "Reporter.py", line 1285, in probe
    TypeError: unsupported
    operand type(s) for /: 'int' and 'NoneType'
    2021-04-16
    01:55:27.442 - ERROR - HWN025032E Job failed during post
    processing of collected data from the data source.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * IBM Storage Insights & Spectrum Control users adding Pure    *
    * Storage FA-X50 with firmware 6.1.5                           *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Adding a Pure Storage FlashArray//X50 fails when the         *
    * device is running firmware 6.1.5.                            *
    *                                                              *
    * The probe log contains these errors:                         *
    *                                                              *
    * HWN025032E Job failed during post processing of              *
    * collected data from the data source.                         *
    *                                                              *
    * HWNEP0135E External process failed with error code 99.       *
    *                                                              *
    * HWN021503E The action cannot be completed                    *
    *                                                              *
    * HWN021709I Collection for storage system Pure Storage        *
    * FlashArray FA-X50 completed.                                 *
    *                                                              *
    * BTADS0102E The probe with the run ID xxxx completed          *
    * with errors.                                                 *
    *                                                              *
    * The array returns a null value for its provisioned space,    *
    * therefore using a manual calculation summing the             *
    * volumes space to allow adding the device to Spectrum         *
    * Control or Storage Insights.                                 *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is targeted for the following releases:
    
    IBM Storage Insights 2Q21   [ 54X-IBM-SI ]
    ( release target 2Q 2021 / June )
    
    IBM Spectrum Control 5.4.3  [ 5.4.3-IBM-SC ]
    ( release target 2Q 2021 / May )
    http://www.ibm.com/support/docview.wss?&uid=swg21320822
    
    The target dates for future releases do not represent a formal
    commitment by IBM. The dates are subject to change without
    notice.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT36677

  • Reported component name

    STORAGE INSIGHT

  • Reported component ID

    5608TPCSI

  • Reported release

    541

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-04-23

  • Closed date

    2021-05-04

  • Last modified date

    2021-05-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STORAGE INSIGHT

  • Fixed component ID

    5608TPCSI

Applicable component levels

  • R540 PSY

       UP

  • R541 PSY

       UP

  • R542 PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSQRB8","label":"IBM Storage Insights"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"541","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date:
08 February 2022