Error description

  • Trace node keeps the file handle opened until the flow get
    stopped and it prevent deletion of the trace node output file
    created by the node while the flow is running. Once the trace
    node is turned off by running mqsichangetrace command, then
    during the processing of the subsequent input message the trace
    node detects that tracing is disabled and then it closes off
    the file handle that it opened.
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of IBM App Connect Enterprise V11.0 and IBM
    Integration Bus V10.0 using the trace node.
    
    
    Platforms affected:
    z/OS, MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    When trace nodes are included in a message flow and they are
    disabled via mqsichangetrace command, the trace node still keeps
    the file handle open until the message flow is stopped . This
    prevents the deletion of the output file created by the trace
    node while the flow is running.
    

Problem conclusion

  • The product has been modified such that output file created by
    trace node can be deleted once the trace nodes are turned off
    using mqsichangetrace command.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v10.0      10.0.0.24
    v11.0      11.0.0.13
    
    The latest available maintenance can be obtained from:
    http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041
    
    If the maintenance level is not yet available,information on
    its planned availability can be found on:
    http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT36353

  • Reported component name

    INTEGRATION BUS

  • Reported component ID

    5724J0540

  • Reported release

    A00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-03-25

  • Closed date

    2021-06-30

  • Last modified date

    2021-06-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INTEGRATION BUS

  • Fixed component ID

    5724J0540

Applicable component levels

[{"Type":"MASTER","Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Version":"All Versions"}]

Document Information

Modified date:
01 July 2021