IBM Support

IT35537: POOL NAMES BEING DISPLAYED INCORRECTLY WHEN LOOKING AT VOLUMES

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • Storage Insights has been observed to display SVC volumes
    associated with pool names that do not exist on the storage
    device that these volumes are hosted on.
    This display issue
    changes over time:
    The volumes will be associated with the
    correct pool names immediately after the daily probe task is
    run; then slowly over the course of the next several hours, the
    volumes no longer show up associated with the correct pools,
    and instead show up in pools that are on systems not
    virtualized by the same SVC.
    The problem is caused by
    event-miniprobe processing; incorrect associations are a
    byproduct of thread-local cache containing identifiers that may
    not be unique.
    
    
    ____________________________________________________
    The
    defect is against component: 5608TPCSI
    Server/Manager
    build/release: 5.4.1
    Problem as described by customer: Pool
    names being displayed incorrectly when looking at
    volumes
    Initial customer impact (low/med/high): med
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * IBM Storage Insights users reviewing SVC Pool info when      *
    * viewing Volumes                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Storage Insights has been observed to display SVC volumes    *
    * associated with pool names that do not exist on the storage  *
    * device that these volumes are hosted on.                     *
    *                                                              *
    * This display issue changes over time:                        *
    * The volumes will be associated with the correct pool names   *
    * immediately after the daily probe task is run; then slowly   *
    * over                                                         *
    * the course of the next several hours, the volumes no longer  *
    * show up associated with the correct pools, and instead show  *
    * up in pools that are on systems not virtualized by the same  *
    * SVC.                                                         *
    *                                                              *
    * The problem is caused by event-miniprobe processing;         *
    * incorrect associations are a byproduct of thread-local cache *
    *                                                              *
    * containing identifiers that may not be unique.               *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is targeted for the following release:
    
    IBM Storage Insights 1Q21   [ 5.4.1-IBM-SI-Patch ]
    IBM Storage Insights 1Q21   [ 54X-IBM-SI ]
    
    ( release target 1Q 2021 / March)
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT35537

  • Reported component name

    STORAGE INSIGHT

  • Reported component ID

    5608TPCSI

  • Reported release

    541

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-01-14

  • Closed date

    2021-04-05

  • Last modified date

    2021-04-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STORAGE INSIGHT

  • Fixed component ID

    5608TPCSI

Applicable component levels

[{"Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSQRB8","label":"IBM Storage Insights"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"541"}]

Document Information

Modified date:
08 February 2022