  • Closed as program error.

Error description

  • If a monitoring event is configured for a node's out terminal
    but that terminal is not actually wired up to any downstream
    node then a monitoring event is not emitted.
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of IBM App Connect Enterprise using monitoring events.
    
    
    Platforms affected:
    MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    Monitoring events of type  'out' terminals are not being
    generated when the terminal is not connected.
     This Apar is applicable to only those nodes (message processing
    nodes) that propagate message to 'out' terminal even if the
    terminal is not wired. For example 'Trace' node, compute node,
     Filter node etc..
    

Problem conclusion

  • The product now generates monitoring events for  the 'out'
    terminal  when the message is propagated to the 'out' terminal
    of message processing node regardless of  whether it is wired to
    downstream nodes or not.
    
    This Apar is not applicable to the nodes that are of  type
    'Output',  like MQOutput node,  Http Reply Node, FileOutput node
    etc..  These nodes being of  the type 'output',  terminate the
    transaction and do no propagate the message further down the
    'out' terminal if they are not wired further. If there is no
    propagation to out terminal,  the event of type 'out' terminal
    will not be emitted by these 'output' nodes.  This is expected
    behaviour.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v11.0      11.0.0.12
    
    The latest available maintenance can be obtained from:
    http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041
    
    If the maintenance level is not yet available,information on
    its planned availability can be found on:
    http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT34846

  • Reported component name

    APP CONNECT ENT

  • Reported component ID

    5724J0550

  • Reported release

    B00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-11-09

  • Closed date

    2021-03-22

  • Last modified date

    2022-11-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    APP CONNECT ENT