IT34616: LOGS SENT BY SEND-ONLY AND GATHER-AND-SEND OF ASSEMBLY LOG ACTION CAN CAUSE AN IMPACT TO CPU USAGE.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Logs sent by send-only and gather-and-send of assmebly log
    action can send data in intervals of 1 second which can lead to
    a lot of work getting queue'd up. The queueing of this workload
    results in the appliance becoming backed up and can lead to an
    increase in CPU usage that may "stick" for unexpected periods
    of time.
    

Local fix

Problem summary

  • When DataPower's log policy is set to send-only or
    gather-and-send mode, it causes the data to bypass the bulk
    upload capability for analytics.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IT34616

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    18X

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-10-20

  • Closed date

    2020-11-19

  • Last modified date

    2020-11-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R18X PSY

       UP

  • RA0X PSY

       UP