IBM Support

IT34507: PROMOTED UDP CONTENTION WHEN 10 OR MORE NODES ARE ADDED TO A MESSAGE FLOW

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • Where nodes of the same type have a promoted property/UDP and
    whose internal names start the same (ie FCMComposite_1_1 and
    FCMComposite_1_10) then, depending on the internal order they
    are sorted in, the nodes may be using the same value for the
    promoted property even if they have been given different values
    in the flow
    

Local fix

  • n/a
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    User of IBM Integration Bus v10 and Application Connect
    Enterprise v11 who use User Defined Properties
    
    
    Platforms affected:
    Linux on x86-64 platform, Windows on x86-64 platform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    If more than ten nodes are present in a flow and there is more
    than one copy of the same subflow in the flow and those subflows
    have a UDP promoted to the main flow then under certain
    circumstances relating to the internal naming of those subflow
    nodes the incorrect UDP value may be used
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IT34507

  • Reported component name

    IIB TOOLKIT

  • Reported component ID

    5724J0541

  • Reported release

    A00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-10-29

  • Closed date

    2021-03-22

  • Last modified date

    2021-03-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    IIB TOOLKIT

  • Fixed component ID

    5724J0541

Applicable component levels

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0"}]

Document Information

Modified date: