Error description
Performance data are no longer collected with message in the performance log: HWNPM2122W No valid performance data was provided by the monitored resource. No performance data records were inserted into the database. In the trace_0.log from the data collector, the moduleInfo doesn't contain the performance information: 2020-08-31 16:11:45.660+0200 [HeartBeat] [SystemActionCache.addSystem] [DEBUG] Received add system action: sysAction = ADD : {"systemID":{"systemType":7,"systemUUID":" ..... moduleInfo={task_total_count=1, DEVICE_TASK_1=time_list} miscProperties=null When it should be: 2020-08-27 06:14:13.187-0700 [pool-2-thread-28566] [SystemActionCache.addSystem] [DEBUG] Received add system action: sysAction = ADD : {"systemID":{"systemType":7,"systemUUID":........... moduleInfo={task_inode_get_perf_counters_perf_module_id_4=3, task_total_count=4, task_inode_get_perf_counters_perf_module_id_3=2, DEVICE_TASK_4=inode_get_perf_counters, task_inode_get_perf_counters_perf_module_id_2=1, DEVICE_TASK_3=inode_get_perf_counters, DEVICE_TASK_2=inode_get_perf_counters, DEVICE_TASK_1=time_list, DEVICE_TASK_ID_ECHO_4=3, DEVICE_TASK_ID_ECHO_3=2, DEVICE_TASK_ID_ECHO_2=1} miscProperties=null Storage Insights goes through all the XIV Modules and looks for the Interface Module. The performance data are collected only if fc_port_count value is different than 0. There is no check for the ethernet port if the fc_port_count value = 0 and then no performance data collected for them.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * IBM Spectrum Control & Storage Insights users monitoring * * performance data of A9000 device * **************************************************************** * PROBLEM DESCRIPTION: * * Performance data is no longer collected for an A9000 device * * with message in the performance log: * * * * HWNPM2122W No valid performance data was provided by the * * monitored resource. No performance data records were * * inserted * * into the database. * * * * Storage Insights goes through all the XIV Modules and looks * * for * * the Interface Module. But the performance data are * * collected * * only if fc_port_count value is different than 0. * * * * There is no check for the ethernet port if the fc_port_count * * value = 0 and then no performance data collected for them. * * * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
The fix for this APAR is targeted for the following release: IBM Storage Insights 1Q21 [ 54X-IBM-SI ] ( release target 1Q 2021 / March ) IBM Spectrum Control 5.4.3 [ 5.4.3-IBM-SC ] ( release target 2Q 2021 / May ) The target dates for future releases do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IT34459
Reported component name
STORAGE INSIGHT
Reported component ID
5608TPCSI
Reported release
540
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-10-06
Closed date
2021-03-24
Last modified date
2021-03-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STORAGE INSIGHT
Fixed component ID
5608TPCSI
Applicable component levels
[{"Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSQRB8","label":"IBM Storage Insights"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"540"}]
Document Information
Modified date:
08 February 2022