APAR status
Closed as program error.
Error description
UUIDs are not populated in the monitoring event in App Connect V11. Provide new eventFormat of WMB_UUID which contains zeros for the UUID.
Local fix
Problem summary
**************************************************************** USERS AFFECTED: All users of App Connect Enterprise version 11 or 12 using Record and Replay with version 10 compatible DataCapture stores. Platforms affected: MultiPlatform **************************************************************** PROBLEM DESCRIPTION: When using WMB format monitoring events the UUID values are not included in monitoring events. Additionally since the UUIDs for Integration Server and Integration Node are not used in App Connect Enterprise version 11 or 12 it is not possible to distinguish events from different Integration Servers or Integration Node's in DataCapture stores.
Problem conclusion
<span style="background-color:rgb(255, 255, 255)">App Co</span><span style="background-color:rgb(255, 255, 255)">nnect enterprise versions</span><span style="background-color:rgb(255, 255, 255)"> 11 and 12 no longer use UUID's to identify Integration Nodes or Integration Servers therefore a new version of the schema for the DataCapture store tables has been introduced that removes these obsolete fields and instead introduces Integration Node hostname</span><span style="background-color:rgb(255, 255, 255)"> and Integration Server hostname</span><span style="background-color:rgb(255, 255, 255)"> fields. </span> The V2 version (DataCaptureSchema_v2.sql) files should be used in preference to the original versions (DataCaptureSchema.sql) when creating the DataCapture store. The original version should be used only for compatibility purposes. Additionally this fix adds an environment variable: MQSI_EVENTMON_USE_OPTIONAL_WMB_ATTRS When this env var is set to any non-null value AND when the output format for events is set to WMB it will result in the messageFlowData elements being populated with UUID attributes. Note that these UUIDs are fixed at all zeroes since these objects no longer actually have UUIDS internally in ACE. For example: Before: <wmb:messageFlowData> <wmb:broker wmb:name="EVENT_TEST" /> <wmb:executionGroup wmb:name="default" /> <wmb:messageFlow wmb:uniqueFlowName="EVENT_TEST.default.httpEcho.httpEcho" wmb:name="httpEcho" wmb:threadId="1823762" /> <wmb:node wmb:nodeLabel="HTTP Input" wmb:nodeType="ComIbmWSInputNode" /> </wmb:messageFlowData> After: <wmb:messageFlowData> <wmb:broker wmb:name="EVENT_TEST" wmb:UUID="00000000-0000-0000-0000-000000000000" /> <wmb:executionGroup wmb:name="default" wmb:UUID="00000000-0000-0000-0000-000000000000" /> <wmb:messageFlow wmb:uniqueFlowName="EVENT_TEST.default.httpEcho.httpEcho" wmb:name="httpEcho" wmb:UUID="00000000-0000-0000-0000-000000000000" wmb:threadId="1824822" /> <wmb:node wmb:nodeLabel="HTTP Input" wmb:nodeType="ComIbmWSInputNode" /> </wmb:messageFlowData> --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v11.0 11.0.0.17 The latest available maintenance can be obtained from: http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041 If the maintenance level is not yet available,information on its planned availability can be found on: http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IT33583
Reported component name
APP CONNECT ENT
Reported component ID
5724J0550
Reported release
B00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-07-17
Closed date
2022-03-02
Last modified date
2022-03-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
APP CONNECT ENT
Fixed component ID
5724J0550
Applicable component levels
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSDR5J","label":"IBM App Connect Enterprise"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B00"}]
Document Information
Modified date:
03 March 2022