Error description

  • A message flow with FileNode which is configured for 'ftps'
    protocol may fail with
    'java.lang.StringIndexOutOfBoundsException: String index out of
    range: 0' exception if the remote FTPS Server returns an empty
    string or a string whose length is less than 3 characters for
    the 'AUTH TLS' command. The systemlog file logs a BIP4367E error
    message.
    
    BIP4367E: The method ''sendData'' in Java node ''File Output''
    has thrown the following exception:
    'java.lang.StringIndexOutOfBoundsException: String index out of
    range: 0'.
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of IBM AppConnect Enterprise V11.0 and IBM Integration
    Bus V10.0 using the File nodes with ftps protocol.
    
    
    Platforms affected:
    MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    A message flow with FileNode which is configured for 'ftps'
    protocol may fail with the following error:
    
    'java.lang.StringIndexOutOfBoundsException: String index out of
    range: 0'
    
    This exception can occur if the remote FTPS Server returns an
    empty string or a string whose length is less than 3 characters
    in response to the 'AUTH TLS' command.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IT33516

  • Reported component name

    INTEGRATION BUS

  • Reported component ID

    5724J0540

  • Reported release

    A00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-07-13

  • Closed date

    2020-08-27

  • Last modified date

    2020-08-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INTEGRATION BUS

  • Fixed component ID

    5724J0540

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
28 August 2020