A fix is available
APAR status
Closed as program error.
Error description
Setting password treatment to none removes the passphrase input dialog from the WebGUI as well as prevents decryption if set to none. If a passphrase is entered it should allow for decryption regarless of password treatment.
Local fix
Set password treatment to masked to allow for decryption using passphrase.
Problem summary
Domain Settings passphrase and password-treatment are not dependant on one another and thus the password treatment should not impact the passphrase encryption of passwords.
Problem conclusion
Remove checks for password-treatment on passphrase encryption decryption. Remove conditional on WebGUI so both fields display unconditionally. Fixed In: 10.0.0.1
Temporary fix
Comments
APAR Information
APAR number
IT33003
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
18X
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-06-19
Closed date
2020-08-13
Last modified date
2020-08-13
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R18X PSY
UP
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateways"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"18X"}]