A fix is available
APAR status
Closed as program error.
Error description
The user observes that... - the error Alert LED in the front panel is ON, - the "show sensors-other" gives "Output Failure" for the PSU - the "test hardware" CLI output shows "Power supply '2' has failed." (or '1'), - the "show ipmi-sel" CLI output shows that PSU1 or PSU2 has "powerSupplyFailureDetected", - but related PSU's LED is GREEN, which means that PSU is still in the normal state and working good. The user observes the "Output Failure" only if removing the power cable less then 6 seconds.
Local fix
Remove the power cable longer than 6 seconds.
Problem summary
After the power off of MQ Alliance, Alert LED in the front panel might be on and the cli command 'show ipmi-sel' might report 'Output Failure' for PSU1 or PSU2. However, the LED of that PSU is still green.
Problem conclusion
Fix is available in 2018.4.1.11 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT32305
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
18X
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-03-25
Closed date
2020-05-04
Last modified date
2020-05-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R770 PSY
UP
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateways"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"18X"}]
Document Information
Modified date: