APAR status
Closed as program error.
Error description
This APAR fixes the following issues. - A manufacturing pack input node fails to receive any messages following a restart of the message flow. - Messages received by the manufacturing input node contain an incorrectly initialised properties folder.
Local fix
NA
Problem summary
**************************************************************** USERS AFFECTED: All users of the IBM Manufacturing Pack on ACE v11 Platforms affected: MultiPlatform **************************************************************** PROBLEM DESCRIPTION: This APAR contains fixes for 2 distinct problems 1) If a message flow containing a manufacturing input node was stopped (mqsistopmsgflow) and then restarted (mqsistartmsgflow), the message flow was not restarted correctly and would not processes any input messages. The application needed to be redeployed or the integration server restarted in order for the message flow to resume processing messages. 2) The 'Properties' folder of an input message received by manufacturing input node was not populated with the correct defaults for the Encoding and CodedCharSetId properties. These properties should be populated with defaults from the Integration Server.
Problem conclusion
1) When the Manufacturing Input Node was running and then stopped, it failed to update it's internal state to stopped. A subsequent start request then took no action as it believed the Input Node was already running running when in-fact it was not. The solution was to correctly change the internal state to stopped when the message flow is stopped. 2) The node framework, upon which the manufacturing pack nodes are built, was incorrectly initializing the Properties folder for each message received. This logic was changed to extract the correct defaults from the Integration Server when building the Properties folder. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v11.0 11.0.0.7 The latest available maintenance can be obtained from: http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041 If the maintenance level is not yet available,information on its planned availability can be found on: http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IT30930
Reported component name
APP CONNECT ENT
Reported component ID
5724J0550
Reported release
B00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-11-13
Closed date
2020-01-21
Last modified date
2020-01-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
APP CONNECT ENT
Fixed component ID
5724J0550
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSDR5J","label":"IBM App Connect Enterprise"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B00","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
21 January 2020