IBM Support

IT30310: ABENDS IN BIPBROKER PROCESS, IMBCONVERTER

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • Abends may occur in the BIPBROKER process. At the top of the
    stack there will be a function setCodePage().
    .
    A possible stack is
    ImbConverter::setCodepage(unsigned int, int, ImbThreadContext*)
    ImbConverter::convertFileNameToNarrow(ImbWstring const&)
    ImbInitialisationData::lookupBrokerHAEnabledWorkPath(ImbWstring
    const&, bool) ImbInitialisationData::DefaultPersistenceProvider
    ::DefaultPersistenceProvider
    .
    ImbInitialisationData::ImbInitialisationData(ImbWstring const&,
    bool, bool)
    .
    ImbCmdLibUnix::testBrokerExistence(ImbWstring const&)
    ImbCmdLib::isBrokerServiceRunning(ImbWstring const&)
    ImbLocalCMPClient::connect(long, int)
    ImbLocalCMPManager::getConnection(ImbWstring const&, int, bool)
    Java_com_ibm_broker_config_proxy_LocalCMPReceiver_
    startLocalCMPNativeReceiverThread
    .
    Together with IT28571 this APAR corrects all known problems in
    ImbConverter.
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of IBM Integration Bus V10 or IBM App Connect
    Enterprise V11
    
    
    Platforms affected:
    z/OS, MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    Abends may occur in the BIPBROKER process. At the top of the
    stack there will be a function setCodePage().
    
    A possible stack is
    ImbConverter::setCodepage(unsigned int, int, ImbThreadContext*)
    ImbConverter::convertFileNameToNarrow(ImbWstring const&)
    ImbInitialisationData::lookupBrokerHAEnabledWorkPath(ImbWstringc
    onst&, bool)
    ImbInitialisationData::DefaultPersistenceProvider::DefaultPersis
    tenceProvider
    .
    ImbInitialisationData::ImbInitialisationData(ImbWstring
    const&,bool, bool)
    .
    ImbCmdLibUnix::testBrokerExistence(ImbWstring const&)
    ImbCmdLib::isBrokerServiceRunning(ImbWstring const&)
    ImbLocalCMPClient::connect(long, int)
    ImbLocalCMPManager::getConnection(ImbWstring const&, int, bool)
    Java_com_ibm_broker_config_proxy_LocalCMPReceiver_startLocalCMPN
    ativeReceiverThread
    .
    This APAR is similar to IT28571.
    

Problem conclusion

  • The abends no longer occur. To activate this APAR and APAR
    IT28671, the environment variable
    MQSI_DISABLE_CONVERTER_CACHE has to be set/exported to any
    value.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v10.0      10.0.0.19
    v11.0      11.0.0.7
    
    The latest available maintenance can be obtained from:
    http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041
    
    If the maintenance level is not yet available,information on
    its planned availability can be found on:
    http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT30310

  • Reported component name

    INTEGRATION BUS

  • Reported component ID

    5724J0540

  • Reported release

    A00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-09-17

  • Closed date

    2019-12-17

  • Last modified date

    2019-12-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INTEGRATION BUS

  • Fixed component ID

    5724J0540

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
17 December 2019