Error description
If flow monitoring of an application is enabled from webui/integration API, then flow monitoring get enabled for all the applications running on the same integration server.
Local fix
n/a
Problem summary
**************************************************************** USERS AFFECTED: All users of IBM App Connect Enterprise V11.0 and IBM Integration Bus V10.0 using flow monitoring. Platforms affected: z/OS, MultiPlatform **************************************************************** PROBLEM DESCRIPTION: If message flow monitoring of an application is enabled from the web user interface, or any administration tool using the Integration API, then message flow monitoring is enabled for all the applications running in the same integration server.
Problem conclusion
The product now correctly enables flow monitoring in the application level. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v10.0 10.0.0.14 v11.0 11.0.0.1 The latest available maintenance can be obtained from: http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041 If the maintenance level is not yet available,information on its planned availability can be found on: http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IT25092
Reported component name
INTEGRATION BUS
Reported component ID
5724J0540
Reported release
A00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-05-18
Closed date
2018-09-19
Last modified date
2018-09-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INTEGRATION BUS
Fixed component ID
5724J0540
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
19 September 2018