Error description

  • When using a url-open which is attempting to process backend
    errors, the url-open may not process backend errors if it is
    first redirected.
    
    For example, when using the urlopen module in GatewayScript and
    the backend responds with a HTTP 400 status code, this will not
    be considered an error from the callback. However, if the backed
    returns a redirect such as a HTTP 302 status code and the
    redirect location returns a HTTP 400 status code this will be
    considered an error in the callback.
    

Local fix

Problem summary

  • When using a url-open which is attempting to process backend
    errors, the url-open may not process backend errors if it is
    first redirected. This causes the url-open to behave differently
     for error handling in the case where redirection occurs when
    compared to the case where no redirection occurs making correct
    error handling difficult.
    

Problem conclusion

  • Fix is available in 7.7.0.0.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT24076

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    760

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-02-22

  • Closed date

    2018-02-23

  • Last modified date

    2018-02-23

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • 0-0
    

Fix information

Applicable component levels

  • R710 PSN

       UP

  • R720 PSN

       UP

  • R750 PSN

       UP

  • R751 PSN

       UP

  • R752 PSN

       UP

  • R760 PSN

       UP

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateways"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"760"}]

Document Information

Modified date:
28 September 2021