A fix is available
APAR status
Closed as program error.
Error description
When there is a network issue or the vCenter / ESXi hosts are heavily loaded, a timeout can happen retrieving CBT data from the vCenter / ESXi hosts. This timeout can lead to a crash of the datamover. IBM Spectrum Protect Versions Affected: IBM Spectrum Protect for Virtual Environments - Dataprotection for VMware 6.4.x, 7.1.x and 8.1.x on all supported platforms. Customer/L2 Diagnostics: The dsmerror.log will show ANS9365E messages ANS9365E VMware vStorage API error for virtual machine 'VMNAME'. TSM function name : RetrievePropertiesEx TSM file : ..\..\common\vm\vmvisdk.cpp 4799 API return code : -1 API error message : Error -1 fault: SOAP-ENV:Client[no subcode] "End of file or no input: Operation interrupted or timed out (1200 s recv delay) (1200 s send delay)" Detail: [no detail] The stack trace will show that the IBM Spectrum Protect Client crashes while retrieving CBT information: ntdll!NtWaitForSingleObject+0xa KERNELBASE!WaitForSingleObjectEx+0x94 dsmcsvc!DiagWriteDump+0x502 dsmcsvc!svcCrashHandler+0x11c KERNELBASE!UnhandledExceptionFilter+0x1a2 ntdll!RtlUserThreadStart$filt$0+0x3e ntdll!_C_specific_handler+0x96 ntdll!RtlpExecuteHandlerForException+0xd ntdll!RtlDispatchException+0x197 ntdll!KiUserExceptionDispatch+0x3a dsmcsvc!std::basic_string<char,std::char_traits<char>,std::alloc ator<char> >::assign+0x90 dsmcsvc!DiskChangeBlockInfo::setSavedChangeId+0x39 dsmcsvc!VmGetVmChangedIds+0x4bc dsmcsvc!VmSendData+0x63d dsmcsvc!vmVddkBackupVM+0x2ddf dsmcsvc!vmBackupVM+0x12c dsmcsvc!tlVMSend+0x142 dsmcsvc!DccTxnConsumer::HandleQueue+0x7e0 dsmcsvc!DccTxnConsumer::Run+0x6f6 dsmcsvc!DccTxnConsumer::DoThread+0xc4 Note: This APAR will be used to correct the crash condition. The timeout issue is outside IBM Spectrum Protect and needs to reviewed separately. Initial Impact: Medium Additional Keywords: TSM, Tivoli, Storage, Manager, TDP, TDP4VE
Local fix
n/a
Problem summary
**************************************************************** * USERS AFFECTED: * * Data Protection for VMware versions 6.4, 7.1 and 8.1 running * * on all Microsoft Windows x64 and Linux x86 platforms. * **************************************************************** * PROBLEM DESCRIPTION: * * See ERROR DESCRIPTION * **************************************************************** * RECOMMENDATION: * * This issue is projected to be fixed in the Data Protection * * for VMware Data Mover version 8.1.4 on Windows x64 and Linux * * x86 platforms. * * Note 1: This is subject to change at the discretion of IBM. * ****************************************************************
Problem conclusion
The network error during CBT query is now correctly handled.
Temporary fix
Comments
APAR Information
APAR number
IT21947
Reported component name
TSM FOR VE DP V
Reported component ID
5725TVEVM
Reported release
81W
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-08-18
Closed date
2017-09-18
Last modified date
2017-09-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
dsmagent
Fix information
Fixed component name
TSM FOR VE DP V
Fixed component ID
5725TVEVM
Applicable component levels
R81W PSY
UP
R81L PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS8TDQ","label":"Tivoli Storage Manager for Virtual Environments"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"81W","Line of Business":{"code":"LOB26","label":"Storage"}}]
Document Information
Modified date: