Fixes are available
APAR status
Closed as program error.
Error description
after changing device name in web gui a new snapshot entry is created on t_res_storage_subsystem_snapshot table with different provided user name. the primary key of this table consists of name, name_format, snapshot_id and for the same name, name_forma t there will be snapshots with different user provided name. the storage system name should be fetched from t_res_storage_subsyst em table where we have just one row for each device and this row has the latest user provided name.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * IBM Spectrum Control 5.2.x users * **************************************************************** * PROBLEM DESCRIPTION: * * IBM Spectrum Control 5.2.x after changing a device name in * * the web GUI a new snapshot entry is created in the database * * table (t_res_storage_subsystem_snapshot). But it is created * * with the new/different name, and the primary key of this * * table consists of name, name_format, snapshot_id and for the * * same name, name_format there will match snapshots with * * different user provided device name. * * * * The Cognos reports containing storage system name should be * * fetched from t_res_storage_subsystem table where it has just * * one row for each device, and this row has the latest user * * provided name. * **************************************************************** * RECOMMENDATION: * * Apply fix maintenance when available * ****************************************************************
Problem conclusion
The fix for this APAR is targeted for the following maintenance package: | refresh pack | 5.2-TIV-TPC-RP0015 - target August 2017 Fixed in IBM Spectrum Control 5.2.15 http://www.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future refresh packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IT20295
Reported component name
TPC
Reported component ID
5608TPC00
Reported release
52B
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-04-20
Closed date
2017-08-03
Last modified date
2017-08-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TPC
Fixed component ID
5608TPC00
Applicable component levels
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSNE44","label":"Tivoli Storage Productivity Center"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"52B"}]
Document Information
Modified date:
24 June 2022