Fixes are available
APAR status
Closed as program error.
Error description
The following message can be see in the ...\TPC\device\log\dmSvcTrace.log: 2017-01-04 04:41:29.625-0600 HWN099993E Number Format exception on and field SLOT_ID @(NAPIPostProcess-XXX.XXX.XXX.XXX_FlashSystem V9000-9846-V9000_xxxxxx-IBM) java.sql.SQLException: Number Format exception on and field SLOT_ID at com.ibm.tpc.infrastructure.mapping.AbstractDBAttributeMapper.set PreparedStatementParameter(AbstractDBAttributeMapper.java:3099) at com.ibm.tpc.infrastructure.mapping.AbstractDBAttributeMapper.set PSParam(AbstractDBAttributeMapper.java:2777) at com.ibm.tpc.infrastructure.mapping.AbstractDBAttributeMapper.att emptUpdate(AbstractDBAttributeMapper.java:2335) at com.ibm.tpc.infrastructure.mapping.AbstractDBAttributeMapper.per sistWithJDBC(AbstractDBAttributeMapper.java:2519) at com.ibm.tpc.infrastructure.mapping.AbstractDBAttributeMapper.per sist(AbstractDBAttributeMapper.java:1118) at com.ibm.tpc.infrastructure.mapping.CLISVC6_LDiskToPhysicalVolume DBMapper.persist(CLISVC6_LDiskToPhysicalVolumeDBMapper.java:362) at com.ibm.tpc.disk.collection.DiskCIMProcessor.persist(DiskCIMProc essor.java:1846) at com.ibm.tpc.discovery.parser.NAPI_DS_SVC_Parser.persistEntity(NA PI_DS_SVC_Parser.java:253) at com.ibm.tpc.discovery.parser.NAPI_DS_SVC_Parser.processOutputFil e(NAPI_DS_SVC_Parser.java:195) at com.ibm.tpc.disk.discovery.SVC_CLI_PostProcess.parse(SVC_CLI_Pos tProcess.java:83) at com.ibm.tpc.disk.discovery.NAPIProbePostProcess.process(NAPIProb ePostProcess.java:418) at com.ibm.tpc.Router.perform(Router.java:642) at com.ibm.tpc.Router.perform(Router.java:403) at com.ibm.tpc.discovery.ProcessProcessor.process(ProcessProcessor. java:71) at com.ibm.tpc.infrastructure.threads.TPCThread.run(TPCThread.java: 262) com.ibm.tpc.disk.collection.DiskCIMProcessor persist FlashSystem SLOT_ID is not reported when the disk is offline. The probe failed because the code checks for the presence of SLOT_ID first, before trying to use it. Affected Storage: FlashSystems
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * IBM Spectrum Control 5.2.x users who collecting data from * * the SVC. * **************************************************************** * PROBLEM DESCRIPTION: * * The issue occurs when SVC returns an invalid slot_id value. * **************************************************************** * RECOMMENDATION: * * Apply fix maintenance when available * ****************************************************************
Problem conclusion
The fix for this APAR was contained in the following maintenance package: | refresh pack | 5.2-TIV-TPC-RP0013 - March 2017 Fixed in IBM Spectrum Control 5.2.13
Temporary fix
Comments
APAR Information
APAR number
IT18712
Reported component name
TPC
Reported component ID
5608TPC00
Reported release
52C
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-01-09
Closed date
2017-04-26
Last modified date
2017-04-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
STORAGE
Fix information
Fixed component name
TPC
Fixed component ID
5608TPC00
Applicable component levels
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSNE44","label":"Tivoli Storage Productivity Center"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"52C"}]
Document Information
Modified date:
24 June 2022