Fixes are available
Fix packs for DataPower Service Gateway version 7.0
Fix packs for DataPower B2B Appliance version 7.0
Fix packs for DataPower Integration Appliance version 7.0
Fix packs for DataPower Gateway version 7.1
Fix packs for DataPower Gateway version 7.2
Fix packs for DataPower Gateway version 7.5
Fix packs for DataPower Gateway version 7.5.1
APAR status
Closed as program error.
Error description
The user observed that DataPower might fail to cancel processing if a FTP Poller Front side Handler (FSH) cannot rename the input file. The user saw this in a setup of two devices with active concurrent FTP Poller FSHs. In rare situations both pollers renamed the input file at the same time. Instead of one canceling the processing on realizing the file got already renamed by its "winning" peer, it proceeded into its processing rule as if all went well on renaming and getting hold of the input file.
Local fix
Problem summary
Affected is use of DataPower FTP Poller Front side Handler. Using two or more FTP pollers to poll a same URL may result in stream error which may cause a same file be picked up more than once.
Problem conclusion
Fix is available in 7.0.0.13, 7.1.0.10, 7.2.0.6 and 7.5.0.2 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT11118
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
600
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-09-09
Closed date
2016-02-24
Last modified date
2016-05-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R700 PSN
UP
R710 PSN
UP
R720 PSN
UP
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateways"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.0"}]
Document Information
Modified date: