Closed as program error.
Error description
After adding switches in the same fabric - 3 different physical fabrics appear for them one for each switch, and then the Logical Fabric changes the parent fabric with the fabric that is last probed. (physical switch contained by the physical fabric last probed.) EXPECTED RESULT: There should be only one Physical fabric since the switches are physically connected, and then the Logical fabric that contains 3 logical switches should have as parent the Physical fabric containing all the 3 physical switches. Additional side effects of this problem include strange things seen in the Web UI: 1. For the Switches panel, the 'Links' information for a physical switch may be wrong. 2. For a physical Switch's detailed view, the Internal Resources menu may incorrectly have no Inter-Switch Connections available, or may list only a subset of the Inter-Switch Connections. 3. For a physical Switch's detailed view, the Internal Resources menu's Ports table may incorrectly list the Connected Resource and Connected Port as 'Unavailable' when the connected port is on a switch that is managed by TPC. 4. The Inter-Switch Link name for a link between two switches may incorrectly only include one of the two managed switches' names. This does not occur if the fabrics were first added using the DCNM SMI Agent.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * TPC 5.1.x and 5.2.x users adding Cisco switches using SNMP * * only * **************************************************************** * PROBLEM DESCRIPTION: * * See ERROR DESCRIPTION. * **************************************************************** * RECOMMENDATION: * * Apply fix maintenance when available. * ****************************************************************
Problem conclusion
The fix for this APAR is targeted for the following maintenance package: | refresh pack | 5.2-TIV-TPC-RP0007 - target August 2015 http://www-01.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future refresh packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IT09640
Reported component name
TPC ADVANCED
Reported component ID
5608TPCA0
Reported release
526
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-06-23
Closed date
2015-06-25
Last modified date
2015-06-25
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
FABRIC
Fix information
Fixed component name
TPC ADVANCED
Fixed component ID
5608TPCA0
Applicable component levels
Document Information
Modified date:
05 October 2023