Fixes are available
Refresh Pack 5.2.6 (June 2015) for Tivoli Storage Productivity Center
Refresh Pack 5.2.7 (August 2015) for Tivoli Storage Productivity Center
IBM Spectrum Control V5.2.8 (December 2015)
IBM Spectrum Control V5.2.9 (February 2016)
IBM Spectrum Control V5.2.10 (May 2016)
IBM Spectrum Control V5.2.10.1 (July 2016)
IBM Spectrum Control V5.2.11 (August 2016)
IBM Spectrum Control V5.2.12 (November 2016)
IBM Spectrum Control V5.2.13 (March 2017)
IBM Spectrum Control V5.2.14 (May 2017)
IBM Spectrum Control V5.2.15 (August 2017)
IBM Spectrum Control V5.2.15.2 (November 2017)
IBM Spectrum Control V5.2.16 (March 2018)
IBM Spectrum Control V5.2.17 (May 2018)
Fix Pack 5.2.7.1 (February 2016) for Tivoli Storage Productivity Center
APAR status
Closed as program error.
Error description
Fabric probes fail - The fabric probe logs will show: BTADS0035E The execution of the job failed with: cm.ibm.db2.jcc.am.SqlException: DB2 SQL Error Error: SQLCODE=-811, SQLSTATE=21000, SQLERRMC=null, DRIVER=3.65.77 This fixes the fabric probe code to better handle the scenario which causes this problem: two or more connections in the database for one proxy node port. RECREATE STEPS: Run TPC fabric probe against BNA CIMOM. Observe described failure ________________________________________________________________ DB2 Version used for Server: N/A The defect is against component: 5508TPC00 Server/Manager build/release (TPC): 5.2.5 ___________________________________________________ Problem as described by customer: Brocade fabric probes fail with BPTDS0035E Initial customer impact (low/med/high): med
Local fix
apply fixing PTF when available
Problem summary
**************************************************************** * USERS AFFECTED: * * TPC 5.2.x users with Brocade switches with IFR ports * **************************************************************** * PROBLEM DESCRIPTION: * * See ERROR DESCRIPTION. * **************************************************************** * RECOMMENDATION: * * Apply fix maintenance when available. * ****************************************************************
Problem conclusion
The fix for this APAR is targeted for the following maintenance package: | refresh pack | 5.2-TIV-TPC-RP0007 - target August 2015 http://www-01.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future refresh packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IT08682
Reported component name
TPC
Reported component ID
5608TPC00
Reported release
525
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-05-01
Closed date
2015-06-26
Last modified date
2015-06-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
FABRIC
Fix information
Fixed component name
TPC
Fixed component ID
5608TPC00
Applicable component levels
R520 PSY
UP
R525 PSY
UP
R526 PSY
UP
Document Information
Modified date:
22 February 2022