Env: z/OS V1.10, CICS TS 3.1 Personal Communications v6.0.8 / Windows7 PC TOSHIBA DYNABOOK R731/C 4 core The customer has a problem about PCOM printer session. They changed from SNA connection to TELNET connection. After that, when they try to print, printing stops still in spooling status. Before(SNA): CICS-VTAM-OSA-PC-5577 printer. After(telnet):CICS-VTAM-TCP/IP(TN3270)-OSA-PC-5577 printer. Windows Spooler shows "spooling". Even if they press the CANCEL button on POCM printer session, print is not canceled. If the session is disconnected, (Communication --> Disconnect) the spool will be printed to the middle.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All PCOM LU3 host print session using TN3270E connectivity * **************************************************************** * PROBLEM DESCRIPTION: * * In a IBM Personal Communications 3270 LU3 host print * * session, the host print data is received with a Write * * Structure Field followed by a Write command with WCC for the * * data. This causes the printer session to hang in spooling * * status. * **************************************************************** * RECOMMENDATION: * **************************************************************** When the printer stops in spooling status, Windows spooler shows "spooling". The print job is not cancelled, even if the CANCEL button is pressed in the printer session. If the session is disconnected (Communication -> Disconnect), the spool is partially printed. However, the problem does not happen over SNA connectivity. When the response byte in the TN3270 header is set to ALWAYS-RESPONSE (0x02), the emulator session must send a TN3270 response after processing the data. When the Write Control Character (WCC) specifies START_PRINT bit on, response must be sent after print data is spooled. So, the timing of sending response is different from that of display data. As a result, telnet layer of IBM Personal Communications needs to recognize the WCC in 3270 data stream. However, the telnet layer was referring to WCC incorrectly when 3270 data stream is constructed by Write Structured Field and the response was not sent to the host. This resulted in session hang. This problem happens on LU3 host print and LU2 host initiated local copy.
Problem conclusion
PCSTLNET.DLL code was corrected to refer to the WCC byte correctly and handle the telnet response. Fix scheduled for PCOM 6.0.12 Refresh Pack
Temporary fix
Comments
APAR Information
APAR number
IT04133
Reported component name
PCOMM V5 COMBO-
Reported component ID
5639I7000
Reported release
601
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-09-02
Closed date
2014-10-15
Last modified date
2014-10-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
PCSTLNET
Fix information
Fixed component name
PCOMM V5 COMBO-
Fixed component ID
5639I7000
Applicable component levels
R601 PSY
UP
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSEQ5Y","label":"Personal Communications"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
15 October 2014