Direct links to fixes
Tivoli Storage Productivity Center Refresh Pack 4
Fix Pack 5.2.4 (November 2014) for Tivoli Storage Productivity Center
Fix Pack 5.2.4.1 (December 2014) for Tivoli Storage Productivity Center
Refresh Pack 5.2.5 (March 2015) for Tivoli Storage Productivity Center (withdrawn)
Fix Pack 5.2.5.1 (April 2015) for Tivoli Storage Productivity Center (withdrawn)
Refresh Pack 5.2.6 (June 2015) for Tivoli Storage Productivity Center
Refresh Pack 5.2.7 (August 2015) for Tivoli Storage Productivity Center
IBM Spectrum Control V5.2.8 (December 2015)
IBM Spectrum Control V5.2.9 (February 2016)
IBM Spectrum Control V5.2.10 (May 2016)
IBM Spectrum Control V5.2.10.1 (July 2016)
IBM Spectrum Control V5.2.11 (August 2016)
IBM Spectrum Control V5.2.12 (November 2016)
IBM Spectrum Control V5.2.13 (March 2017)
IBM Spectrum Control V5.2.14 (May 2017)
IBM Spectrum Control V5.2.15 (August 2017)
IBM Spectrum Control V5.2.15.2 (November 2017)
IBM Spectrum Control V5.2.16 (March 2018)
IBM Spectrum Control V5.2.17 (May 2018)
Fix Pack 5.2.7.1 (February 2016) for Tivoli Storage Productivity Center
APAR status
Closed as program error.
Error description
The following BTADS0083W message should be treated as INFO rather than WARNING and it should not affect the probe status. 2014-07-16 09:41:18.973-0700 BTADS0083W Some or all information may not be collected for fabric/fabrics since agent/agents are not configured and/or not currently operational. Fabric probe for fabric 3000000573AC1111 has some limitations. For switch 200000059B7A2222 following information will not be collected - Topology Information,Cisco Physical Infrastructure Information,Active Zone Configuration Information,Full Zone Database Information For switch 2000000DEC433333 following information will not be collected - Topology Information,Cisco Physical Infrastructure Information,Active Zone Configuration Information,Full Zone Database Information For switch 2000002A6A545555 following information will not be collected - Topology Information,Cisco Physical Infrastructure Information,Active Zone Configuration Information,Full Zone Database Information For switch 2000547FEECB6666 following information will not be collected - Topology Information,Cisco Physical Infrastructure Information,Active Zone Configuration Information,Full Zone Database Information For switch 2000547FEEE77777 following information will not be collected - Topology Information,Cisco Physical Infrastructure Information,Active Zone Configuration Information,Full Zone Database Information
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * TPC 5.1.x and 5.2.x users running fabric probes * **************************************************************** * PROBLEM DESCRIPTION: * * See ERROR DESCRIPTION. * **************************************************************** * RECOMMENDATION: * * Apply fix maintenance when available. Until then, probes in * * some situations may always end with warning. * ****************************************************************
Problem conclusion
BTADS0083I has replaced BTADS0083W and applies to the same situation. Some information may not be available with certain agents but that is noted and considered normal. The fix for this APAR is targeted for the following maintenance package: | refresh pack | 5.2-TIV-TPC-RP0004 - target November 2014 http://www-01.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future refresh packs or fix packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IT03219
Reported component name
TPC
Reported component ID
5608TPC00
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-07-18
Closed date
2014-09-22
Last modified date
2014-09-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
FABRIC
Fix information
Fixed component name
TPC
Fixed component ID
5608TPC00
Applicable component levels
R522 PSY
UP
Document Information
Modified date:
23 March 2022