Fixes are available
Fix packs for DataPower XML Security Gateway version 6.0
Fix packs for DataPower B2B Appliance version 6.0
Fix packs for DataPower Integration Appliance version 6.0
Fix packs for DataPower Low Latency Appliance version 6.0
Fix packs for DataPower Service Gateway version 6.0
Fix packs for DataPower Service Gateway version 6.0.1
Fix packs for DataPower B2B Appliance version 6.0.1
Fix packs for DataPower Integration Appliance version 6.0.1
APAR status
Closed as program error.
Error description
Appliances with the HSM crypto feature and using crypto operations while under load might find the appliance performs a restart recovery.
Local fix
Reduce load or reduce number of crypto operations invoked from processing policy.
Problem summary
Appliances with the HSM feature might restart while performing cryptographic operations while under load.
Problem conclusion
Fix is available in 5.0.0.16, 6.0.0.8, and 6.0.1.4 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT01563
Reported component name
DTPWR INTGRAPL
Reported component ID
DP905XI52
Reported release
500
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-05-05
Closed date
2014-07-28
Last modified date
2014-08-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DTPWR INTGRAPL
Fixed component ID
DP905XI52
Applicable component levels
R500 PSY
UP
R600 PSY
UP
R601 PSY
UP
R700 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSHT9H","label":"WebSphere DataPower Integration Appliance XI52"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.0.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
05 August 2014