Fixes are available
Refresh Pack 5.2.2 (June 2014) for Tivoli Storage Productivity Center
Refresh Pack 5.2.3 (August 2014) for Tivoli Storage Productivity Center
Fix Pack 5.2.4 (November 2014) for Tivoli Storage Productivity Center
Fix Pack 5.2.4.1 (December 2014) for Tivoli Storage Productivity Center
Refresh Pack 5.2.5 (March 2015) for Tivoli Storage Productivity Center (withdrawn)
Fix Pack 5.2.5.1 (April 2015) for Tivoli Storage Productivity Center (withdrawn)
Refresh Pack 5.2.6 (June 2015) for Tivoli Storage Productivity Center
Refresh Pack 5.2.7 (August 2015) for Tivoli Storage Productivity Center
IBM Spectrum Control V5.2.8 (December 2015)
IBM Spectrum Control V5.2.9 (February 2016)
IBM Spectrum Control V5.2.10 (May 2016)
IBM Spectrum Control V5.2.10.1 (July 2016)
IBM Spectrum Control V5.2.11 (August 2016)
IBM Spectrum Control V5.2.12 (November 2016)
IBM Spectrum Control V5.2.13 (March 2017)
IBM Spectrum Control V5.2.14 (May 2017)
IBM Spectrum Control V5.2.15 (August 2017)
IBM Spectrum Control V5.2.15.2 (November 2017)
IBM Spectrum Control V5.2.16 (March 2018)
IBM Spectrum Control V5.2.17 (May 2018)
Fix Pack 5.2.7.1 (February 2016) for Tivoli Storage Productivity Center
APAR status
Closed as program error.
Error description
Cisco 9710 switches with WWNs like xxxx002A6Axxxxxx are not found during discovery. Other switches with different values in the middle of the WWN are found.
Local fix
Update the T_RES_OUI table to add the new value of 002A6A and associate it with Cisco. Please run these commands from DB2 command line: connect to TPCDB; set schema tpc; insert into T_RES_OUI values ('002A6A','Cisco'); Restart the Device server.
Problem summary
**************************************************************** * USERS AFFECTED: * * TPC 5.2.1 and earlier users who have Cisco switches with a * * WWN such as xxxx002A6Axxxxxx. * **************************************************************** * PROBLEM DESCRIPTION: * * Some Cisco switches are not found during CIMOM discovery * * even though others managed by the same DCNM instance are. * * The center value (OUI) is used to identify the switch as * * being from Cisco and handle it correctly. * **************************************************************** * RECOMMENDATION: * * Apply fix maintenance when available or apply the steps in * * the local fix to update the database manually in the * * meantime. * ****************************************************************
Problem conclusion
The fix for this APAR is targeted for the following maintenance package: | fix pack | 5.1.1-TIV-TPC-FP0004 - target July 2014 | refresh pack | 5.2-TIV-TPC-RP0002 - target June 2014 http://www-01.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future refresh packs or fix packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IT00606
Reported component name
TPC
Reported component ID
5608TPC00
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-03-28
Closed date
2014-03-31
Last modified date
2014-03-31
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
FABRIC
Fix information
Fixed component name
TPC
Fixed component ID
5608TPC00
Applicable component levels
R510 PSY
UP
R511 PSY
UP
R520 PSY
UP
R521 PSY
UP
Document Information
Modified date:
23 March 2022