IBM Support

IJ54464: SYNCVG -Q MAY CORE DUMP IF MULTIPLE SYNCVG IS RUN CONCURRENTLY APPLIES TO AIX 7300-04

 

APAR status

  • Closed as program error.

Error description

  • When multiple syncvg commands run concurrently, syncvg -q
    may core dump with the following stack:
    
    malloc_y(0x300164d8, 0x0, 0xf085a400, 0x0, 0x0,
    0x73000000, 0x63, 0xf0231964) at 0xd012fbfc
    malloc_common@AF105_87(??) at 0xd0112384
    malloc@AF104_99(??) at 0xd01122ec
    strdup@AF5_3(??) at 0xd01fa144
    odm_set_path(??) at 0xd0605ec8
    get_vgname(??, ??) at 0xd06895d0
    syncvg_prt_query(??) at 0x100021c0
    syncvg_prt() at 0x10002358
    main(??, ??) at 0x100003bc
    

Local fix

Problem summary

  • syncvg -q may show incorrect output including invalid command
    names and pids, especially if multiple syncvg are running at
    the same time.
    syncvg -q may also core dump
    

Problem conclusion

  • Correct how information is transferred between user and kernel
    space during syncvg -q
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ54464

  • Reported component name

    AIX V7.3

  • Reported component ID

    5765CD300

  • Reported release

    730

  • Status

    CLOSED PER

  • HIPER

    NoHIPER

  • Submitted date

    2025-04-21

  • Closed date

    2025-04-21

  • Last modified date

    2025-12-10

  • APAR is sysrouted FROM one or more of the following:

    IJ54181

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX V7.3

  • Fixed component ID

    5765CD300