IBM Support

IJ50595: IN THE MANAGE INSPECTIONS FORMS, WRONG NUMBERS ARE DISPLAYED WHEN MAKING CONDITIONAL SETTINGS FOR GROUPED QUESTIONS.

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • STEPS TO REPRODUCE:
    
    1. Go to Manage Inspections Forms and create a form.
    
    2. Create a question with a single choice as first question and
    make sure the status is required and visible.
    
    
    3. Add more sub-questions to this question, such as Time Only,
    File Upload, and Text Response. Make sure these sub-questions'
    status are non-required and non-visible.
    
    
    4. Save the question and duplicate it twice.
    
    5. Click white box in front of question 1 and create groups for
    question 1.
    
    6. Then do the same for question 2 and question 3 and save the
    form.
    
    7. Click Conditional Settings icon.
    
    RESULTS:
    The system displays sub-question numbered as 1.001.04.
    Note: This issue can occur randomly.
    
    EXPECTED RESULTS:
    The sub-question should be numbered as 1.001.01 instead.
    
    8. Select sub-question 1.001.04 and click on Add Condition.
    
    
    9. Click on the magnifying glass icon from "Select a response
    field".
    
    
    10. From "Select A Response Field" list, select 1.01.02 Time.
    
    RESULTS:
    The system displays the selected response field as 1.001.03
    Time.
    
    EXPECTED RESULTS:
    That should be 1.01.02 Time instead.
    
    REPORTED IN VERSION:
    IBM Maximo Asset Management 7.6.1.3
    

Local fix

Problem summary

  • ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * IN THE MANAGE INSPECTIONS FORMS, WRONG NUMBERS ARE DISPLAYED *
    * WHEN MAKING CONDITIONAL SETTINGS FOR GROUPED QUESTIONS.      *
    ****************************************************************
    

Problem conclusion

  • Work Center Manage Inspection form is deprecated from Manage 9.0
    onwards. This issue will be fixed in prior versions.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ50595

  • Reported component name

    SYSTEM CONFIG

  • Reported component ID

    5724R46S1

  • Reported release

    761

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-03-22

  • Closed date

    2024-06-21

  • Last modified date

    2024-06-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    SYSTEM CONFIG

  • Fixed component ID

    5724R46S1

Applicable component levels

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSLKT6","label":"Maximo Asset Management"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
21 June 2024