APAR status
Closed as program error.
Error description
Inspection form shows the following error BMXAA2890E irrespective of the values entered in the run hours field. STEPS TO REPRODUCE: 1.Login to Maximo Application. 2.Navigate to Assets Application. 3.Create new asset and provide TESTASSET as asset number 4.Go to Meters tab a->Add New Meter and provide below details - Meter = RUNHOURS - Average calculation method = ALL - reading type value = ACTUAL - last reading value = 100 - last reading date = Current Date 5. Change the status of Asset to Active and Save new asset 6. Navigate to Manage Inspection Forms 7. Click on Create Form - Enter name = TEST. - Form Type = Inspection - Click on Add question and enter question = counter - Click meter readings from response fields - Enter description for meter readings = Runhours - Enter name of the meter = Runhours - Click on Done Button - Click on SAVE Button 8. Navigate to Work Order Tracking Application 9. Create a new work order - Enter description as e. g. Test with inspection from - Select Asset as TESTASSET (Created in Step3) - Select value in Inspection Form as TEST (Created in Step 7) - Click on SAVE button to save the record 10.Go to field Inspection Result - Navigate to Go to Conduct an Inspection - Click on button Start - Enter run hours value 5 - Again, enter run hours value as 105 ACTUAL RESULT: Irrespective of the values entered the following error message is displayed "BMXAA2890E The new Reading (5) entered on 1/18/24 should be greater than the previous reading (100.00) entered on 1/17/24 9:50 PM unless the new reading is a delta or meter RUNHOURS on Asset TESTASSET has a roll over value and Rollover is selected" EXPECTED RESULT: Error message should not be displayed. REPORTED IN VERSION: Tivoli's process automation engine 7.6.1.3-IFIX20231223-1405
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * MAXIMO * **************************************************************** * PROBLEM DESCRIPTION: * * Inspection form shows the following error, BMXAA2890E * * irrespective of the values entered in the run hours field. * ****************************************************************
Problem conclusion
This will be fixed in a future release.
Temporary fix
Comments
APAR Information
APAR number
IJ49930
Reported component name
MAXIMO ASST MGM
Reported component ID
5724R46AM
Reported release
761
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-02-02
Closed date
2024-03-28
Last modified date
2024-03-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
MAXIMO ASST MGM
Fixed component ID
5724R46AM
Applicable component levels
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSLKT6","label":"Maximo Asset Management"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
04 April 2024