Error description

  • Problem Description
    User changed the attribute type and length to IN23 OOB attribute
    to ITEM object and completed the changes with no error.
    
    While user is trying to create a PO from a PR under more
    actions, the following error message is showing up.
    BMXAA7816E - Operation setValue(double value) is not supported
    on: Data type=null, Value=1.0293847561029385E49, Object
    name=POLINE, Attribute name=PLIN5. Report the error to your
    system administrator.
    
    
    
    STEPS TO REPRODUCE:
    
    1) Go to Database configuration and bring up ITEM object
    Under Attributes tab filter by IN23
    Change type to ALN (original was decimal)
    Change length to 12 (original was 15 and scale 2)
    Save
    The following objects and attributes will change as well:
    SERVICEITEMS - 	IN23
    TOOLITEM	- IN23
    TOOLINV	- IN23
    PRLINE	 - RLIN5
    RFQLINE	- RFQLIN5
    REORDERPAD	- IN23
    POLINE	 - PLIN5
    SKDEXTRACAPTOOLVIEW	- IN23
    2) From IN23 attribute >Ddomain filed, navigate to Domains
    application and create a new domain:
    Domain id: IBM
    Data Type: ALN
    Length: 10
    Add some values as:
    1200000000 - Value 1
    9999900000 - Value 2
    1510151000 - Value 3
    2300000000 - Value 4
    3000000000 - Value 5
    OK
    Return with the value or complete as IBM the Domain field
    
    3) Add the domain IBM to all attributes of the affected objects.
    
    Save and apply configuration changes
    
    
    4) Go to PR application and crate a new PR
    Complete all required fields and add a PRLine
    
    Save and Approve it
    
    5) Under More Actions > Create PO > Autonumber
    
    RESULTS: The following message pops up on the screen BMXAA7816E
    - Operation setValue(double value) is not supported on: Data
    type=null, Value=1.0293847561029385E49, Object name=POLINE,
    Attribute name=PLIN5. Report the error to your system
    administrator.
    
    EXPECTED RESULTS: It should be possible to create the PO since
    all attributes that are affected by the change also have the
    associated domain.
    
    REPORTED IN VERSION:  Tivoli's process automation engine 7.6.1.3
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * MAXIMO                                                       *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * BMXAA7816E - OPERATION SETVALUE(DOUBLE VALUE) IS NOT         *
    * SUPPORTED ON: DATA TYPE=NULL, VALUE=1.0293847561029385E49,   *
    * OBJECT NAME=POLI                                             *
    ****************************************************************
    

Problem conclusion

  • This will be fixed in a future release.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ49675

  • Reported component name

    MAXIMO ASST MGM

  • Reported component ID

    5724R46AM

  • Reported release

    761

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-01-08

  • Closed date

    2024-01-17

  • Last modified date

    2024-01-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    MAXIMO ASST MGM

  • Fixed component ID

    5724R46AM

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"Maximo Asset Management"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
17 January 2024