Error description

  • ERROR DESCRIPTION:
    Integrity Checker error with duration domain
    
    PROBLEM:
    Customer reported that Integrity Checker is returning the
    following errors, when running it in report mode:
    BMXAA0443E -- Error - BMXAA0534E -- A domain of type
    DOMAIN_NAME01 should have a valid datatype and length., Domain
    NUMERIC has a maxtype of DURATION and a length of 8.
    
    BMXAA0443E -- Error - BMXAA0534E -- A domain of type
    DOMAIN_NAME02 should have a valid datatype and length., Domain
    NUMERIC has a maxtype of DURATION and a length of 8.
    
    PERFORMANCE ISSUE:
    No.
    
    STEPS TO REPRODUCE:
    1. Go to Domains application;
    2. Add new NUMERIC Domain, with a datatype of DURATION and
    length of 8 and save;
    3. Go to Database configuration application;
    4. Select any object;
    5. Go to the attributes tab and select the option create a new
    attribute
    6. Set the attribute type to DURATION;
    7. Add the previously created domain to the attribute details;
    8. Save the changes;
    9. Activate Admin Mode and apply the configuration changes;
    10. Run integrity checker in report mode.
    
    CURRENT ERRONEOUS RESULT:
    Por que o resultado é inesperado
    When integrity checker is executed, an error message related to
    an invalid domain configuration is returned, even with a valid
    configuration. The error message seems to be inverting the
    domain id and domain type, making a valid DURATION domain
    configuration return as invalid by Integrity Checker.
    
    EXPECTED RESULT:
    The expected result is that the Integrity checker error message
    does not appear with the provided configuration (NUMERIC Domain,
    with a datatype of DURATION and length of 8).
    
    ENVIRONMENT (SYSTEM INFO):
    Tivoli's process automation engine 7.6.1.2-IFIX20221229-1044
    Build 20200715-0100 DB Build V7612-284 HFDB Build HF7612-151
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Maximo administrators                                        *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Integrity Checker error: BMXAA0534E ? A domain of type       *
    * DOMAIN_NAME01 should have a valid datatype and length.,      *
    * Domain                                                       *
    * NUMERIC has a maxtype of DURATION and a length of 8.         *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR will be contained in a future release.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ49376

  • Reported component name

    MAXIMO SYSTEMS

  • Reported component ID

    5724R46AV

  • Reported release

    761

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-12-01

  • Closed date

    2024-05-06

  • Last modified date

    2024-05-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    MAXIMO SYSTEMS

  • Fixed component ID

    5724R46AV