APAR status
Closed as program error.
Error description
ERROR DESCRIPTION: Integrity Checker error with duration domain PROBLEM: Customer reported that Integrity Checker is returning the following errors, when running it in report mode: BMXAA0443E -- Error - BMXAA0534E -- A domain of type DOMAIN_NAME01 should have a valid datatype and length., Domain NUMERIC has a maxtype of DURATION and a length of 8. BMXAA0443E -- Error - BMXAA0534E -- A domain of type DOMAIN_NAME02 should have a valid datatype and length., Domain NUMERIC has a maxtype of DURATION and a length of 8. PERFORMANCE ISSUE: No. STEPS TO REPRODUCE: 1. Go to Domains application; 2. Add new NUMERIC Domain, with a datatype of DURATION and length of 8 and save; 3. Go to Database configuration application; 4. Select any object; 5. Go to the attributes tab and select the option create a new attribute 6. Set the attribute type to DURATION; 7. Add the previously created domain to the attribute details; 8. Save the changes; 9. Activate Admin Mode and apply the configuration changes; 10. Run integrity checker in report mode. CURRENT ERRONEOUS RESULT: Por que o resultado é inesperado When integrity checker is executed, an error message related to an invalid domain configuration is returned, even with a valid configuration. The error message seems to be inverting the domain id and domain type, making a valid DURATION domain configuration return as invalid by Integrity Checker. EXPECTED RESULT: The expected result is that the Integrity checker error message does not appear with the provided configuration (NUMERIC Domain, with a datatype of DURATION and length of 8). ENVIRONMENT (SYSTEM INFO): Tivoli's process automation engine 7.6.1.2-IFIX20221229-1044 Build 20200715-0100 DB Build V7612-284 HFDB Build HF7612-151
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: * * Maximo administrators * **************************************************************** * PROBLEM DESCRIPTION: * * Integrity Checker error: BMXAA0534E ? A domain of type * * DOMAIN_NAME01 should have a valid datatype and length., * * Domain * * NUMERIC has a maxtype of DURATION and a length of 8. * ****************************************************************
Problem conclusion
The fix for this APAR will be contained in a future release.
Temporary fix
Comments
APAR Information
APAR number
IJ49376
Reported component name
MAXIMO SYSTEMS
Reported component ID
5724R46AV
Reported release
761
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-12-01
Closed date
2024-05-06
Last modified date
2024-05-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
MAXIMO SYSTEMS
Fixed component ID
5724R46AV
Applicable component levels
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSLKT6","label":"Maximo Asset Management"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
07 May 2024