IBM Support

IJ47954: APPLICATION IMPORT - ISSUE WHEN MAXIMUM COUNT IN OBJECT STRUCTURE IS SET TO 0

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • Problem Description:
    When the Maximum count in Object Structure is set to 0, data is
    imported into Maximo for Flat File type, while for XML type the
    record is not imported.
    
    Steps:
    
    1.) Enable application import:
    
    Navigate to Integration --> Object Structure, Filter by MXITEM.
    
    Under More Actions, Select Add/Modify Application Import Support
    Option.
    
    Click on New Row:
    
    Add the Application: ITEM
    
    Default File Type: XML
    Maximum Count: 0
    
    Save it.
    
    Go to Security Groups --> Open MAXADMIN --> Applications tab -->
    Item Master
    
    Grant access to Application Import option and save it.
    
    Log out and log in again.
    
    
    2.) Navigate to Inventory --> Item Master
    
    Select Application Import --> Object Structure: MXITEM
    
    
    Import the following XML:
    
    <?xml version="1.0" encoding="UTF-8"?>
    <SyncMXITEM xmlns="http://www.ibm.com/maximo"
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    creationDateTime="2023-03-29T18:24:56+01:00" transLanguage="EN"
    baseLanguage="EN" messageID="3026916801106962797898"
    maximoVersion="7 6 20200715-0100 V7612-284">
    <MXITEMSet>
    <ITEM>
    <ITEMNUM>TESTCV</ITEMNUM>
    <DESCRIPTION>TEST</DESCRIPTION>
    <ITEMSETID>SET1</ITEMSETID>
    <STATUS>PENDING</STATUS>
    </ITEM>
    </MXITEMSet>
    </SyncMXITEM>
    
    Results:
    BMXAA7953I - The import was successful and 0 records were
    processed.
    
    Expected Results
    Application should treat setting maxcount=0 as unlimited
    
    System Information:
    IBM Tpae Integration Framework 7.6.1.3
    

Local fix

Problem summary

  • ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * ISSUE WHEN MAXIMUM COUNT IN OBJECT STRUCTURE IS SET TO 0     *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is contained in the future release
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ47954

  • Reported component name

    INTEGRATION

  • Reported component ID

    5724R46I1

  • Reported release

    761

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-08-21

  • Closed date

    2024-05-09

  • Last modified date

    2024-05-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • _MAXIMO_
    

Fix information

  • Fixed component name

    INTEGRATION

  • Fixed component ID

    5724R46I1

Applicable component levels

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSLKT6","label":"Maximo Asset Management"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
10 May 2024