APAR status
Closed as program error.
Error description
When the application is set to "is mobile" in application designer, the conditional properties do not work. Read only date field allows changes when using the DATELOOKUP Lookup Button. When using a normal "non-mobile" application, you get an error as expected, but on the mobile app, it lets you change the report date. STEPS TO REPRODUCE: 0- Open Maximo as maxadmin 1-Create a security group in security groups application 2-after that create an user and associate that user to the security group you just created 3-ensure that you add a conditional property to the target start date in the workorder tracking application in the application designer application (sigoption READ, any condition like 1=1, and property inputmode set value to readonly when the condition is true) 4-ensure that the workorder tracking application is set to "Is Mobile" and then save application 5-log out Maximo 6-log back in as the new user you just created 7-when you try to go to the work order tracking application and insert a new record you will notice that the target start date can be modified if you select a date using the calendar control and you are able to save Conclusion: Apparently when the application is set to "is mobile" in application designer, the conditional properties do not work CURRENT ERRONEOUS RESULT: when the application is set to "is mobile" in application designer, the conditional properties do not work EXPECTED RESULT: when the application is set to "is mobile" in application designer, the conditional properties work fine ENVIRONMENT (SYSTEM INFO): App Server IBM WebSphere Application Server 9.0.5.10 Version Tivoli's process automation engine 7.6.1.2-IFIX20230628-1650 Build 20200715-0100 DB Build V7612-284 HFDB Build HF7612-182 IBM Maximo Asset Management Work Centers 7.6.0.4 Build 20200715-0100 DB Build V7604-119 HFDB Build HF7680-10 IBM Maximo Asset Management Scheduler 7.6.8.0 Build 20200715-0100 DB Build V7680-148 HFDB Build HF7680-34 IBM Tpae Integration Framework 7.6.1.2 Build 20200615-2330 DB Build V7612-11 BPD Essentials - Drag and Drop 7.6.1.0 Build 20200920-1100 DB Build V7610-04 IBM Maximo Asset Management 7.6.1.2 Build 20200715-0100 DB Build V7611-01 IBM Maximo for Transportation 7.6.2.6 Build 20200804-1646 DB Build V7626-16 IoT Connection Utility 7.6.0.3 Build 20200701-1409 DB Build V7603-32 Server OS Windows Server 2016 10.0 Server DB Microsoft SQL Server 13.0 (13.00.6430)
Local fix
Problem summary
**************************************************************** * PROBLEM DESCRIPTION: * * WHEN THE APPLICATION IS SET TO "IS MOBILE" IN APPLICATION * * DESIGNER, THE CONDITIONAL PROPERTIES DO NOT WORK * ****************************************************************
Problem conclusion
The fix for this APAR will be included in a future release
Temporary fix
Comments
APAR Information
APAR number
IJ47863
Reported component name
SYSTEM CONFIG
Reported component ID
5724R46S1
Reported release
761
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-08-10
Closed date
2023-10-03
Last modified date
2023-10-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SYSTEM CONFIG
Fixed component ID
5724R46S1
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"Maximo Asset Management"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
03 October 2023