IBM Support

IJ47621: AFTER APPLYING THE 7.6.1.2 IFIX34, MAXIMO IS REPLACING THE "&" TO "%C2%B6" FOR ANY URL THAT IS CONFIGURED WITH THE "&PARA".

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • PROBLEM:
    After applying the  7.6.1.2 ifix34, Maximo is replacing the "&"
    to "%C2%B6" for any URL that is configured with the "&para".
    
    
    PERFORMANCE ISSUE:
    No
    
    STEPS TO REPRODUCE:
    1- Open the Work Order application;
    2- Clink in the attachment icon;
    3- Add new attachment > Add new web page;
    4- Enter the link:
    https://localhost/viewOnlyQuery/paramName=wc_controlledDocument
    &paramValue=wc_controlledDocument&paramType=type/paramName=wc_n
    umber&paramValue=E-005-00081&paramType=property&operator=OPERAT
    OR_EQUALS/paramName=wc_sheet&paramValue=0001&paramType=property
    &operator=OPERATOR_EQUALS/paramName=wc_type&paramValue=DRAWING&
    paramType=property&operator=OPERATOR_EQUALS/paramName=wc_status
    &paramValue=APPROVED&paramType=property&operator=OPERATOR_EQUAL
    S/paramName=aw_status&paramValue=Approved&paramType=property&op
    erator=OPERATOR_EQUALS/
    
    5- Go to View attachment and open the link.
    
    Note that the link will not open and note that the & is been
    replaced by the %C2%B6.
    
    https://localhost/viewOnlyQuery/paramName=wc_controlledDocument
    %C2%B6mValue=wc_controlledDocument%C2%B6mType=type/paramName=wc
    _number%C2%B6mValue=ALR%2000-005D%C2%B6mType=property&operator=
    OPERATOR_EQUALS/paramName=wc_sheet%C2%B6mValue=
    
    
    CURRENT ERRONEOUS RESULT:
    The link will not open and note that the &para is been replaced
    by the %C2%B6.
    
    EXPECTED RESULT:
    The link should be available without replace the & by the %C2%B6
    
    
    ENVIRONMENT (SYSTEM INFO):
    Tivoli's process automation engine 7.6.1.2-IFIX20230628-1650
    Build 20200715-0100 DB Build V7612-284 HFDB Build HF7612-182
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * MAXIMO                                                       *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * AFTER APPLYING THE 7.6.1.2 IFIX34, MAXIMO IS REPLACING THE   *
    * "&" TO "%C2%B6" FOR ANY URL THAT IS CONFIGURED WITH THE      *
    * "&PARA".                                                     *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is contained in the following maintenance
    package: release\fix pack for Release 8.x Product
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ47621

  • Reported component name

    MAXIMO ASST MGM

  • Reported component ID

    5724R46AM

  • Reported release

    761

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-07-17

  • Closed date

    2023-08-29

  • Last modified date

    2023-08-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    MAXIMO ASST MGM

  • Fixed component ID

    5724R46AM

Applicable component levels