Error description
ERROR DESCRIPTION: Attribute Initialize Value Launch Point not working for YORN field in Automation Script PROBLEM: Using an automation script with an attribute initialize value launch point for a YORN field, we see the error below when trying to add a new record in the application: BMXAA4118I - The Boolean field is blank and requires a value. PERFORMANCE ISSUE: N STEPS TO REPRODUCE: 1. Go to Database Configuration; 2. Search for LABOR object; 3. In Attributes tab, create a custom attribute called BBQUALIFIED; 4. Fill in title, description and choose YORN as type. Fill in the default value with 0 or 1; 5. Apply Configuration Changes; 6. Go to Application Designer; 7. Search for LABOR application; 8. Click Labor tab; 9. Add a textbox; 10. Right click textbox and click Properties; 11. For attribute, type BBQUALIFIED; 12. Save the changes; 13. Go to Automation Scripts; 14. Create a Script with Attribute Launch Point; 15. Fill in Launch point and description, choose LABOR for object and BBQUALIFIED as attribute; 16. Select 'Initialize Value' as event and click next; 17. Fill in script and description. Log level as error, jython as script languade and click next; 18. Add the code: if (not mbo.isNew() and mbo.getString('TYPE') != ''): if(True): mbo.setValue("BBAQUALIFIED",1,MboConstants.NOACCESSCHECK); 19. Click create; 20. Go to Labor Application; 21. Click new labor. CURRENT ERRONEOUS RESULT: In UI: BMXAA4118I - The Boolean field is blank and requires a value. EXPECTED RESULT: A new record should be created. ENVIRONMENT (SYSTEM INFO): Tivoli's process automation engine 7.6.1.2-IFIX20220628-1241 Build 20200715-0100 DB Build V7612-284 HFDB Build HF7612-129,
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: * * MAXIMO * **************************************************************** * PROBLEM DESCRIPTION: * * Attribute initialize value launch point not working for YORN * * field in automation script * ****************************************************************
Problem conclusion
The fix for this APAR is contained in the following maintenance package: release\fix pack for Release 8.x Product
Temporary fix
Comments
APAR Information
APAR number
IJ47606
Reported component name
SYSTEM CONFIG
Reported component ID
5724R46S1
Reported release
761
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-07-14
Closed date
2024-02-07
Last modified date
2024-02-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SYSTEM CONFIG
Fixed component ID
5724R46S1
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"Maximo Asset Management"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
07 February 2024