Error description
Customer was attempting to migrate to a new set of SVCs, and found that the normal process of creating relationships on the SVCs did not work as expected.
Local fix
Manually delete all relationships on the SVCs, and then add them to the PowerHA configuration, one at a time, with a verify and sync between additions.
Problem summary
Creating multiple relationships in a single consistency group from PowerHA is failing. Only 1st configured relationship is getting created but with master and auxilary disk names of last relationship configured
Problem conclusion
Done code changes to fetch proper Master and auxilary disks name that are configured for that relationship