IJ45671: HA APPLICATION MONITORING SUSPEND/RESUME NOT HANDLED CORRECTLY

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • The PowerHA cluster manager is supposed to reject changes
    to the application monitor function unless the cluster
    state is ST_STABLE. However, if the cluster is in a state
    such as ST_RP_FAILED and an attempt is made to suspend
    application monitoring, the application state will be
    changed to "ONLINE MONITOR SUSPENDED", but the
    application
    monitor(s) will not be suspended.
    This application state prevents either suspend or resume
    of application monitoring, even after the cluster state
    has been returned to ST_STABLE.
    

Local fix

  • Check to make sure that the cluster manager is in state
    ST_STABLE on all nodes before attempting to suspend or
    resume application monitoring.   However, once the
    mismatched state has occurred, this can be corrected
    only by stopping and restarting PowerHA cluster services
    on that node.
    

Problem summary

  • If user trying to suspend or resume the application when the
    cluster is not ST_STABLE state below message is seen in the
    clstrmgr.debug file even though suspend is failed
    Resource::setState: Resource APP_CON is already 6, return
    

Problem conclusion

  • Using the clmgr manage suspend/resume application command from
    the smit to prevent application suspend or resume if cluster is
    not in ST_STABLE state.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ45671

  • Reported component name

    POWERHA SYSMIR

  • Reported component ID

    5765H3900

  • Reported release

    727

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-03-02

  • Closed date

    2023-03-02

  • Last modified date

    2023-03-02

  • APAR is sysrouted FROM one or more of the following:

    IJ44074

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    POWERHA SYSMIR

  • Fixed component ID

    5765H3900

Applicable component levels

[{"Business Unit":{"code":"BU008","label":"Security"},"Product":{"code":"SGL4G4","label":"PowerHA"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"727"}]

Document Information

Modified date: