Error description
Solaris OS servers with No Scan Data due to 'improper' 'LparCapacity' value (this can be verified by looking into cit_capacity_xxx_tlm_hw scans). Example: <LparCapacity>0.007812</LparCapacity> ILMT logic does not handle values smaller than 0.01. Error in ILMT import.log: no LPAR layer or its data was incomplete (make sure the scanner on the endpoint is in the latest version)! - HW scan data will be discarded Troubleshooting the issue: 1 - Enable import debug in ILMT via Management > Advanced Server Settings, and change the value of the debug_logging_for_imports parameter to true. 2 - Perform a single capacity scan for this server as per https ://www.ibm.com/docs/en/license-metric-tool?topic=configuration- step-5-initiating-capacity-scan-all-computers#t_initiating_capa city_scan 3 - Run ILMT import via Management -> Data Imports WARN: [ILMTCore] (ImportCapacity-Thread:0) validateHwScanDataConsistency - Error: no LPAR layer or its data was incomplete (make sure the scanner on the endpoint is in the latest version)! - HW scan data will be discarded DEBUG: [ILMTCore] (ImportCapacity-Thread:0) com.ibm.ilmt.common.util.exceptions.IBMSlmException com.ibm.ilmt.common.util.exceptions.IBMSlmException: CODIF8150E at com.ibm.ilmt.core.etl.core.actions.hwscan.SolarisHwScan.vali dateHwScanDataConsistency(SolarisHwScan.java:1033) ... WARN: [ILMTCore] (ImportCapacity-Thread:0) CapacityScanFileHandler::processTask::Some error occured during importing the capacity scan from file : ./tlm_hw_XXXX_YYYY.xml for endpoint : ZZZZ. DEBUG: [ILMTCore] (ImportCapacity-Thread:0) CapacityScanFileHan dler::processTask:com.ibm.ilmt.common.util.exceptions.IBMSlmExc eption:CODIF8150E at com.ibm.ilmt.core.etl.core.actions.hwscan.SolarisHwScan.vali dateHwScanDataConsistency(SolarisHwScan.java:1033) TS011940625
Local fix
Please contact ILMT Support.
Problem summary
**************************************************************** ***************** ERROR DESCRIPTION: Solaris OS servers with No Scan Data due to 'improper' 'LparCapacity' value (this can be verified by looking into cit_capacity_xxx_tlm_hw scans). Example: <LparCapacity>0.007812</LparCapacity> ILMT logic does not handle values smaller than 0.01. Error in ILMT import.log: no LPAR layer or its data was incomplete (make sure the scanner on the endpoint is in the latest version)! - HW scan data will be discarded Troubleshooting the issue: 1 - Enable import debug in ILMT via Management > Advanced Server Settings, and change the value of the debug_logging_for_imports parameter to true. 2 - Perform a single capacity scan for this server as per https ://www.ibm.com/docs/en/license-metric-tool?topic=configuration- step-5-initiating-capacity-scan-all-computers#t_initiating_capa city_scan 3 - Run ILMT import via Management -> Data Imports WARN: [ILMTCore] (ImportCapacity-Thread:0) validateHwScanDataConsistency - Error: no LPAR layer or its data was incomplete (make sure the scanner on the endpoint is in the latest version)! - HW scan data will be discarded DEBUG: [ILMTCore] (ImportCapacity-Thread:0) com.ibm.ilmt.common.util.exceptions.IBMSlmException com.ibm.ilmt.common.util.exceptions.IBMSlmException: CODIF8150E at com.ibm.ilmt.core.etl.core.actions.hwscan.SolarisHwScan.vali dateHwScanDataConsistency(SolarisHwScan.java:1033) ... WARN: [ILMTCore] (ImportCapacity-Thread:0) CapacityScanFileHandler::processTask::Some error occured during importing the capacity scan from file : ./tlm_hw_XXXX_YYYY.xml for endpoint : ZZZZ. DEBUG: [ILMTCore] (ImportCapacity-Thread:0) CapacityScanFileHan dler::processTask:com.ibm.ilmt.common.util.exceptions.IBMSlmExc eption:CODIF8150E at com.ibm.ilmt.core.etl.core.actions.hwscan.SolarisHwScan.vali dateHwScanDataConsistency(SolarisHwScan.java:1033) TS011940625 **************************************************************** ***************** * EXPECTED RESULTS: * The issue does not occur. **************************************************************** * RECOMMENDATION: Apply appropriate update when available. ****************************************************************
Problem conclusion
The fix for this APAR is contained in the following maintenance packages: | Update | ILMT 9.2.31.0 ****************************************************************
Temporary fix
Comments
APAR Information
APAR number
IJ45254
Reported component name
LIC METRIC TOOL
Reported component ID
5724LMTEM
Reported release
920
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-02-07
Closed date
2023-02-08
Last modified date
2023-02-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
LIC METRIC TOOL
Fixed component ID
5724LMTEM
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS8JFY","label":"IBM License Metric Tool"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"920","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
09 February 2023