IBM Support

IJ43743: MOVE/MODIFY 2 ASSETS WITH THE SAME ROTATING ASSET (INITIALLY IN REPAIR LOCATION) TO CENTRAL LOCATION IT FAILS WITH BMXAA4211E OR

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • PROBLEM:
    We have 2 Assets with the same Rotating Asset (itemnum) in
    REPAIR location. If we select both and Move/Modify at the same
    time to move them to CENTRAL location we get:
    BMXAA4211E - Replicate batch asset move or;  BMXAA8229W record
    INVCOST has been updated by another user.
    
    STEPS TO RECREATE:
    1) Go to Assets application > Select 2 or more Assets that are
    at a REPAIR location with the same ITEMNUM = PUMP100.
    2) Select Action Move/Modify Assets.
    3) Move to an Inventory storeroom eg. CENTRAL > apply and OK.
    4) Error BMXAA8229W - Record INVCOST: Item =PUMP100
    Location=CENTRAL Condition Code= Site=BEDFORD Item Set=SET1 has
    been updated by another user. Your changes have not been saved.
    Refresh the record and try again.
    5) Click Cancel.
    6) In List view Assets it shows REPAIR location which is wrong.
    7) Refresh then the assets show in CENTRAL location.
    
    RESULTS:
    BMXAA8229W record INVCOST has been updated by another user.
    Assets are moved.
    
    EXPECTED RESULTS:
    The Assets should be moved without an error.
    
    REPORTED IN VERSION:
    Tivoli's process automation engine 7.6.1.2-IFIX20220426
    

Local fix

  • N/A
    

Problem summary

Problem conclusion

  • A fix for this APAR will be included in a future release.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ43743

  • Reported component name

    MAXIMO ASST MGM

  • Reported component ID

    5724R46AM

  • Reported release

    761

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-10-09

  • Closed date

    2023-05-09

  • Last modified date

    2023-05-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    MAXIMO ASST MGM

  • Fixed component ID

    5724R46AM

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"Maximo Asset Management"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
09 May 2023