Error description
PROBLEM DESCRIPTION: When running Reschedule/Unassign Assignments in Work Order Tracking error below is being shown: BMXAA1580E - A Java Message System (JMS) error occurred. Check the JMS setup in the administrator console for the server. STEPS: -Go to Work Order Tracking -Filter for just a couple work orders. -From the list view, use the select action 'Reschedule/Unassign Assignments' -Press ok to apply to all work orders. -Choose a new scheduled start date, and press ok. You need to repeat the last step as many times as websphere's Maximum connections defined for connection fatory (default is 10) Error in the logs: CWSIA0005E: The JCA runtime failed to allocate a connection. javax.jms.JMSException: CWSIA0005E: The JCA runtime failed to allocate a connection. at com.ibm.ws.sib.api.jms.impl.JmsManagedConnectionFactoryImpl. createConnection(JmsManagedConnectionFactoryImpl.java:217) at com.ibm.ws.sib.api.jms.impl.JmsManagedConnectionFactoryImpl. createConnection(JmsManagedConnectionFactoryImpl.java:144) at psdi.iface.jms.JMSClient.createConnection(JMSClient.java:485) at psdi.iface.jms.JMSClient.createSession(JMSClient.java:462) System Information: Tivoli's process automation engine 7.6.1.2-IFIX20211022-0031 Build 20200715-0100 DB Build V7612-284 HFDB Build HF7612-50
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * MAXIMO * **************************************************************** * PROBLEM DESCRIPTION: * * When running Reschedule/Unassign Assignments in Work Order * * Tracking error below is being shown: BMXAA1580E - A Java * * Message System (JMS) error occurred. Check the JMS setup in * * the administrator console for the server. * ****************************************************************
Problem conclusion
The fix for this APAR is contained in the following maintenance package: release\fix pack for Release 8.x Product
Temporary fix
Comments
APAR Information
APAR number
IJ42199
Reported component name
MAXIMO ASST MGM
Reported component ID
5724R46AM
Reported release
761
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-08-29
Closed date
2023-01-30
Last modified date
2023-01-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
MAXIMO ASST MGM
Fixed component ID
5724R46AM
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"Maximo Asset Management"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
30 January 2023