IBM Support

IJ40895: TEPSLOGIN FAILS WITH ERROR KUICTL099E

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • Connecting to the TEPS using the command 'tacmd tepslogin'
    fails returning the error messages:
     KUICTL099E The tepsLogin command failed because an unexpected
    error occurred. Please consult the
    /opt/IBM/ITM/logs/TepsLoginCLI_0.log log file to determine the
    cause of the error.
    An unexpected system error occurred while executing the
    tepsLogin command.
    The TepsLoginCLI_0.log file may provide more information about
    this error. If you require further assistance resolving the
    error, contact IBM Software Support.
    

Local fix

  • Workaround:
    For Unix and Linux systems add the following text line to the
    Tivoli Enterprise Portal Server's configuration file
    $CANDLEHOME/config/cq.ini (Unix/Linux).
    
    KFW_ORB_ENABLED_PROTOCOLS=TLS_Version_1_2_Only For Windows
    systems add the following text line to the TEPS' configuration
    by selecting Advanced->Edit ENV File and then adding the
    following
    
    
    KFW_ORB_ENABLED_PROTOCOLS=TLS_Version_1_2_Only
    

Problem summary

  • TEPSLOGIN FAILS WITH ERROR KUICTL099E
    

Problem conclusion

  • Fix delivered in SP13
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ40895

  • Reported component name

    TEMS

  • Reported component ID

    5724C04MS

  • Reported release

    630

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-06-28

  • Closed date

    2023-06-02

  • Last modified date

    2023-06-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TEMS

  • Fixed component ID

    5724C04MS

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSZ8F3","label":"IBM Tivoli Monitoring V6"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630"}]

Document Information

Modified date:
03 June 2023