IBM Support

IJ40423: PROPERTY MXE.SCRIPT.RELOADPERSCRIPT SOMETIMES IGNORED WHEN PUSHING AUTOMATION SCRIPT.

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • Problem Desscription:
    
    When creating a new script via MIF, everything is fine, only
    this script is reloaded. When updating an existing script, the
    whole ScriptCache is reloaded, as it was before setting
    mxe.script.reloadperscript to true.
    
    While the ScriptCache reloads, most of the automations do not
    work.
    
    
    Steps to reproduce
    
    1. Set  mxe.script.reloadperscript property to true.
    
    2. Create a simple script:
    
    pass
    
    # Just a Test
    
    
    3. And for the Update:
    
    pass
    
    # Just a Second Test
    
    
    Current results:
    
    If script is created/updated this via the UI, the following log
    messages can be seen:
    
    
    [2/8/22 10:02:18:999 CET] 0000042c SystemOut O [INFO]
    [CL_ICD_DEAS112FSCCD01] [] [maximo] BMXAA6447I - Reload
    RELOADTEST3 from SCRIPT into the maximo cache.
    [2/8/22 10:03:04:993 CET] 0000056d SystemOut O [INFO]
    [CL_ICD_DEAS112FSCCD01] [] [maximo] BMXAA6447I - Reloading
    RELOADTEST3 from SCRIPT to the Maximo cache.
    
    If script is created/updated this via MIF, the following message
    shows:
    
    [2/8/22 10:04:49:879 CET] 0000060a SystemOut O [INFO]
    [CL_ICD_DEAS112FSCCD01] [] [maximo] BMXAA6447I - Reloading
    RELOADTEST4 from SCRIPT into the Maximo cache.
    [2/8/22 10:05:15:456 CET] 00000609 SystemOut O [INFO]
    [CL_ICD_DEAS112FSCCD01] [] [maximo] BMXAA6444I - Reloading
    SCRIPT into the Maximo cache.
    
    On update the ScriptCache for this script needs to be reloaded.
    With the introduction of systemproperty
    mxe.script.reloadperscript, this should be only the script that
    got changed. This is ways faster and less interrupting. For ~700
    Scripts active and reloading all takes between 8 and 15 seconds
    (depends on the current server load). Reloading a single script
    is done within milliseconds and also does not affect all other
    scripts. In those 8 to 15 seconds, nearly no script works
    correctly.
    
    Expected results:
    
    The script reload should work even if updated from UI.
    
    Environment:
    
    Tivoli's process automation engine 7.6.1.2
    

Local fix

  • n/a
    

Problem summary

  • ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * When `mxe.init.reloadperscript` is enabled and an existing   *
    * auto script is updated via MIF, the entire scripting cache   *
    * is reloaded.                                                 *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR will be contained in a future release.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ40423

  • Reported component name

    MAXIMO ASST MGM

  • Reported component ID

    5724R46AM

  • Reported release

    761

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-06-03

  • Closed date

    2022-09-20

  • Last modified date

    2022-09-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    MAXIMO ASST MGM

  • Fixed component ID

    5724R46AM

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"Maximo Asset Management"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
20 September 2022