IBM Support

IJ39691: COMPUTER RECONCILIATION NOT WORKING. SQL ERRORCODE: -206 ERROR IN IMPORT LOG

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • The issue occurs if you enable the computer_reconciliation_mode
    setting on Management > Advanced Server Settings panel in ILMT
    and at least one datasource configured is in version 9.2 or 9.5
    below patch 5 of BigFix.
    The error causes the reconciliation feature to not work on that
    particular datasource (so the endpoints moved to that
    datasource won't be reconciled with the endpoints already
    present in the ILMT).
    
    
    
    
    
    
    
    
    
    
    
    
    
    TS007489575
    

Local fix

  • Upgrade the offending datasource to BigFix version at least 9.5
    patch 5. This issue does not affect reconciliation to other
    datasources though, so it can be neglected if that feature is
    not required to work on the affected datasource.
    

Problem summary

  • ****************************************************************
    *****************
    ERROR DESCRIPTION:
    
    The issue occurs if you enable the computer_reconciliation_mode
    
    setting on Management > Advanced Server Settings panel in ILMT
    
    and at least one datasource configured is on one of the early
    
    patches of 9.2 or 9.5 version below patch 5 of BigFix.
    
    The error causes the reconciliation feature to not work on that
    
    particular  datasource (so the endpoints moved to that
    
    datasource  won't be reconciled with the endpoints already
    
    present in the ILMT).
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    TS007489575
    
    ****************************************************************
    *****************
    * EXPECTED RESULTS:
    * The issue does not occur.
    ****************************************************************
    * RECOMMENDATION: Apply appropriate update when available.
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is contained in the following maintenance
    packages:
     | Update | ILMT 9.2.28.0
    ****************************************************************
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ39691

  • Reported component name

    LIC METRIC TOOL

  • Reported component ID

    5724LMTEM

  • Reported release

    920

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-04-28

  • Closed date

    2022-05-16

  • Last modified date

    2022-05-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    LIC METRIC TOOL

  • Fixed component ID

    5724LMTEM

Applicable component levels

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS8JFY","label":"IBM License Metric Tool"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"920"}]

Document Information

Modified date: