Error description

  • PRLINE line type "Item" and line type "std service", Technical
    Terms revision number not copied over to POLINE or RFQ LINE. An
    Item that does not have a particular Technical Term
    associated to it. When that Item is added to PRLINE line and
    the "add/detete technical terms"
    action is performed, adding an additional technical term to the
    PRLINE Item. The PRLINE will display correctly the technical
    term's revision number. However when the copy PRLINEs to
    PO or RFQ is initiated the techncial terms  revision number is
    not carried over to PO or RFQ.
    The same problem happens with the PRLINE type =Standard Service.
    When the "add/delete technical terms" action is initated from
    the PRLINE adding an additional technical term, the additional
    technical term revision number is displayed correctly .  However
    when the copy PRLINEs to PO or RFQ  is initiated the technical
    term revision number is not carried over to the PO or RFQ.
    
    
    STEPS TO  REPRODUCE
    
    1)Terms and Conditions (NUC) create TERM1 - revision =1, TERM2 -
    revision = 1
    
    PRLINE Line Type = Item:
    PR to PO
    2)PR(NUC) create new PR -TESTNUC1 , Vendor Compay = BEX
    3)PRLINE> click "New Row" line type = Item (select item with no
    technical terms associated at item level)
    4)more actions > select "Add/Delete Technical Terms" >click "New
    Row"
    5)select item added to PRLINE (step #3) > select  Term = TERM1 >
    click "ok"
    6)take note Technical Terms , Revision number displayed
    7)Approve PR.
    8)PO(NUC) create new PO> TESTPO1 > Vendor company = BEX
    9)more actions > click copy PRLINE > select PR -TESTNUC1 (from
    step#2).
    10)POLINE > check Technical Terms , Term value and Description
    are copied to POLINE however the revision number is blank
    This is not correct , Term , Description  and Revsion number
    should all be copied to the POLINE
    ................................................................
    PR to RFQ
    1)PR(NUC) create new PR -TESTNUC2 , Vendor Compay = BEX
    2)PRLINE> click "New Row" line type = Item (select item with no
    technical terms associated at item level)
    3)more actions > select "Add/Delete Technical Terms" >click "New
    Row"
    4)select item added added to PRLINE (step #3) > select Term =
    TERM1 > click "ok"
    5)take note Technical Terms , Revision number displayed
    6)Approve PR.
    7)RFQ(NUC) create new RFQ> TESTRFQ1
    8)more actions > click copy PRLINE > select PR -TESTNUC2 (from
    step#1).
    9)RFQ > check Technical Terms , Term value and Description are
    copied to RFQ LINE however the revision number is blank
    This is not correct , Term , Description and Revsion number
    should all be copied to the RFQ LINE
    
    xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
    
    PRLINE Line Type = Standard Service:
    PR to PO
    1) PR(NUC) create PR=TESTNUC3 > Vendor Company BEX
    2)PRLINE > click "New Row" line type = Standard Service > select
    FREIGHT
    3)more actions > select "Add/Delete Technical Terms" click "New
    Row"
    4)item = FREIGHT . Term = TERM2 > click "ok"
    5)Take note Technical Terms , Revision number displayed
    6)PO(NUC) create new PO> TESTPO2 > Vendor company = BEX
    7)more actions > click copy PRLINE > select PR -TESTNUC3 (from
    step#1).
    8)POLINE > check Technical Terms , Term value and Description
    are copied to POLINE however the revision is blank
    This is not correct ,Term,Desciription and Revsion number should
    all be copied to the POLINE
    ................................................................
    PR to RFQ
    1) PR(NUC) create PR=TESTNUC4 > Vendor Company BEX
    2)PRLINE > click "New Row" line type = Standard Service > select
    FREIGHT
    3)more actions > select "Add/Delete Technical Terms" click "New
    Row"
    4)item = FREIGHT . Term = TERM2 > click "ok"
    5)Take note Technical Terms , Revision number displayed
    6)RFQ(NUC) create new RFQ> TESTRFQ2 > Vendor company = BEX
    7)more actions > click copy PRLINE > select PR -TESTNUC4 (from
    step#1).
    8)RFQ> check Technical Terms , Term value and Description are
    copied to RFQ Line however the revision is blank
    This is not correct ,Term, Desciription and Revsion number
    should all be copied to the RFQ LINE
    
    
    RESULTS:
    PRLINE type =Item ,when the Item has no Technical Terms
    associated at the item level when you
    add addtional Technical Terms through the PR to the Item, only
    the Technical Term Value and Description are copied to POLINE
    and RFQ LINE the revsion number is Blank.
    PRLINE type = Standard Service, when addtional Technical Terms
    are added to the Standard Service through the PR only the
    Technial Term Value, and Description are copied to
    the POLINE and RFQ Line, the revision number is blank even
    though in all cases the PRLINE displays the Technical Term
    revision number.
    
    
    EXPECTED RESULTS:
    When copying PRLINE to POLINE/ RFQ for line type Item or line
    type Standard Service, the Technical Term revsion number should
    be copied over.
    
    
    REPORTED IN VERSION:
    IBM Maximo for Nuclear Power  7.6.1.0 & 7.6.2.0
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * IBM Maximo for Nuclear Power 7.6.2.0 users.                  *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Technical Term "Revision #" field value not copied over to   *
    * RFQ or PO from PR line.                                      *
    ****************************************************************
    

Problem conclusion

  • A change in the code was made to fix the issue.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ39204

  • Reported component name

    MAXIMO FOR NUCL

  • Reported component ID

    5724R5300

  • Reported release

    762

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-04-05

  • Closed date

    2022-05-03

  • Last modified date

    2022-05-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    MAXIMO FOR NUCL

  • Fixed component ID

    5724R5300

Applicable component levels

[{"Line of Business":{"code":"LOB59","label":"Sustainability Software"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLL8M","label":"Maximo for Nuclear Power"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"762"}]

Document Information

Modified date:
04 May 2022