  • Closed as program error.

Error description

  • If Tivoli monitoring Service pack 7 or later is installed on a
    system where ITM home directory contains spaces (e.g. c:\Program
    Files\IBM\ITM ) the installation will fail and the following
    error will be logged:
    
    
    Bad return code from cmd /c
    %ITMPATCH_DIR%\bundles\WINDOWS\setup.exe /w /Update /z"/sf%ITMP
    ATCH_DIR%\bundles\WINDOWS\deploy\SP_Silent_Install.txt"/s /f2"%C
    

Local fix

Problem summary

  • Service pack install failure.  Viewing the patchlog.log showed
    that setup.exe failed with either rc = -3 or rc = a very large
    negative number.  Occasionally this was reported as occurring on
    machines installing to a non-default folder (eg c:\program files
    (x86)\ibm\itm), but that may not have been a true correlation.
    

Problem conclusion

  • The "large negative number" that was occasionally reported
    resolved to 0xC0000409 which is a Windows stack buffer overflow
    error.  Indicated module was GSKit.
    
    
    The fix for this APAR is contained in the following maintenance
    packages:
    
       | service pack | 6.3.0.7-TIV-ITM-SP0012
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ38062

  • Reported component name

    OMEG DIST INSTA

  • Reported component ID

    5608A41CI

  • Reported release

    630

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-02-24

  • Closed date

    2022-05-02

  • Last modified date

    2022-05-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    OMEG DIST INSTA

  • Fixed component ID

    5608A41CI

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
08 March 2023