Closed as program error.
Error description
It is not possible to complete an inspection if a meter reading is entered and removed (later), thus attempting to complete the inspection without a (not mandatory) reading taken. STEPS TO REPRODUCE: 1. Go to Manage Inspection Forms and create a new form: Name: METER FORM Select Form Type: Inspectin Add Question Question: Meter Reading Test Response Field column > Asset Date > Meter Readings Description: Meter Readings Meter: HEAD LOSS2 Visible and NO Required Done, Save and Active it 2. Go to Work Order Tracking Application and create a new work order Asset: TRACK 1 Inspection Forms: The inspection created above Save Thee Inspection Result field will be filled > Detail Menu > Go to Conduct an Inspection 3. In the Conduct an Inspection, start the inspection, choose any value in the Meter Readings Click on Save and exit The Conduct an Inspection screen will close. 4. Again in the Work Order Tracking application, in the Inspection Result field > Detail Menu > Go to Conduct an Insepction 5. In the Conduct an Inspection, start the inspection, uncheck the value that was chosen in step 3 Click on Complete Expected Result: The inspection should be completed as the response is not mandatory. . Result: Got the following error message: "BMXAA2880E - New reading, new reading date and new reading inspector values are required to enter a new reading. " Version of Maximo: 7612 - Work Center 7604 Application within Maximo: Conduct an Inspection
Local fix
na
Problem summary
Problem conclusion
A fix for this APAR will be included in a future release.
Temporary fix
Comments
APAR Information
APAR number
IJ36247
Reported component name
SYSTEM CONFIG
Reported component ID
5724R46S1
Reported release
761
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-11-23
Closed date
2023-04-04
Last modified date
2023-04-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SYSTEM CONFIG
Fixed component ID
5724R46S1
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"Maximo Asset Management"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
04 April 2023