APAR status
Closed as program error.
Error description
The Asset Reverse Traceability report does not show the reverse traceability for the individual tool used at calibration. Steps to reproduce ? In Tools application select or create a tool having rotating flag checked. Change status to Active and Tools/organization status to Active. Note the tool number. Referenced to as TOOL1. ? In Asset application create an active asset having TOOL1 as Rotating item. Note the asset number. Referenced to as ASSET1 ? In Work order tracking application create a work order for any other asset number. Note the asset number. Referenced to as ASSET2. In Plans / Tools add a row for TOOL1. Approve the work order. Note the work order number. Referenced to as WO1. ? In Actuals / Tools click on planned tools and select TOOL1. Expand the row. In Rotating asset, click on Select value. Select ASSET1. Complete the work order. ? Go to Asset application. Click on More Actions / Run Reports. ? Run report Asset Traceability. Select asset ASSET2. In the report validate that the following is listed for asset ASSET2: Work order WO1, Rotating Asset ASSET1. ? In Asset application, click on More Actions / Run reports. ? Run report Asset Reverse Traceability. Select ASSET1. The expected result is that the following should be listed for ASSET1: Work order WO1, Asset ASSET2. Instead, no result is presented. ? Now run the Asset Reverse Traceability report again. Select ASSET2. The report is now presenting for ASSET2: Work order WO1, Asset ASSET2. It now looks like ASSET2 has been used to calibrate itself. Expected outcome The Asset Reverse Traceability report should present the result like what is presented in the View Tool Usage dialog in Asset application. Environment: Tivoli's process automation engine 7.6.0.10
Local fix
n/a
Problem summary
**************************************************************** * USERS AFFECTED: * * MAXIMO * **************************************************************** * PROBLEM DESCRIPTION: * * The Asset Reverse Traceability report does not show the * * reverse * * traceability for the individual tool used at calibration. * **************************************************************** * RECOMMENDATION: * * In some instances it might be required to manually import * * asset_reverse_traceability.rptdesign using Report * * Administration application. * ****************************************************************
Problem conclusion
The fix for this APAR was included in 7.6.1.3 GA and Manage 8.4. It will be fixed in an IFIX for 7.6.1.2.
Temporary fix
Comments
APAR Information
APAR number
IJ35280
Reported component name
MAXIMO REPORTIN
Reported component ID
TIVOREPTS
Reported release
761
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-10-01
Closed date
2023-09-11
Last modified date
2023-09-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
MAXIMO REPORTIN
Fixed component ID
TIVOREPTS
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"Maximo Asset Management"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
11 September 2023