IBM Support

IJ34668: ROCE ADAPTER SENDING LLDP MULTICAST CAUSES NETWORK FAILURE APPLIES TO AIX 7200-05

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • If etherchannel is configured in NIB Mode on top of Mellanox
    adapters, then during primary to backup port fail over time we
    may face poor network performance. This is because the failed
    primary port also send LLDP packets to the switch and hence the
    switch get confused on the port failure.
    

Local fix

Problem summary

  • If etherchannel is configured in NIB Mode on top of Mellanox
    adapters, then during primary to backup port fail over time we
    may face poor network performance. This is because the failed
    primary port also send LLDP packets to the switch and hence the
    switch get confused on the port failure.
    

Problem conclusion

  • Enabled users to regulate LLDP sending behavior of adapter.
    

Temporary fix

Comments

  • 7200-05 - use AIX APAR IJ34668
    

APAR Information

  • APAR number

    IJ34668

  • Reported component name

    AIX V7.2

  • Reported component ID

    5765CD200

  • Reported release

    720

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2021-08-23

  • Closed date

    2021-08-23

  • Last modified date

    2021-10-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    U890352

Fix information

  • Fixed component name

    AIX V7.2

  • Fixed component ID

    5765CD200

Applicable component levels

  • R720 PSY U890352

       UP21/09/08 I 1000

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSVEF8"},"Platform":[{"code":"PF053","label":"Power Systems"}],"Version":"720","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]

Document Information

Modified date:
04 October 2021