Error description

  • Error Message:
    A GPF event is received when Java is trying to walk the Java
    stack .
    .
    Stack Trace:
      libj9prt29.so+0x263fa : 0x263fa <mainSynchSignalHandler+554>
        [../../omr/port/unix/omrsignal.c:1070]
      libpthread.so.0+0xf630
      libj9vm29.so+0x9c28c : 0x9c28c <iterateStackTrace+1804>
        [exceptiondescribe.c:380]
      libjclse29.so+0x1e4d5 : 0x1e4d5 <getStackTrace+165>
        [common/jclexception.c:361]
      Java_java_lang_J9VMInternals_getStackTrace+0x30
    (0x00002B7CB39D03F0 [libjclse29.so+0x1b3f0])
    

Local fix

  • The issue can be worked around using the -Xshareclasses:none
    option to disable the shared classes cache.
    

Problem summary

  • The problem is caused when a wrong copy of the J9RomClass or the
    wrong number of ROMMethod count are used.
    

Problem conclusion

  • The JVM has been updated to ensure the correct copy of the
    J9ROMClass and the correct number of the ROMMethod count are
    used
    .
    This APAR will be fixed in the following Java Releases:
       8    SR6 FP35  (8.0.6.35)
    .
    Contact your IBM Product's Service Team for these Service
    Refreshes and Fix Packs.
    For those running stand-alone, information about the available
    Service Refreshes and Fix Packs can be found at:
               https://www.ibm.com/developerworks/java/jdk/
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ33306

  • Reported component name

    J9 COMMON CODE

  • Reported component ID

    620700127

  • Reported release

    270

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-06-17

  • Closed date

    2021-06-22

  • Last modified date

    2021-07-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    J9 COMMON CODE

  • Fixed component ID

    620700127

Applicable component levels

  • R270 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSNVBF","label":"Runtimes for Java Technology"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]

Document Information

Modified date: