Error description

  • The following error is shown on importing a Work Order record
    through the Enterprise Service.
    
    BMXAA1891E - The available balance
    will become negative as a result of
    this transaction.
    
    STEPS TO RECREATE:
    1) From [Organizations], open EAGLENA.
    Then, from [Select Action]-[Inventory Options]-
    [Inventory Defaults], check the following
    check boxes.
    
    Disallow Negative Balance
    Disallow Negative Available Balance
    
    Log out and log back in to Maximo for the change to
    take effect.
    
    2) From [Item Master] application, create a new
    item as below.
    
    Item : TESTITEM
    Description : TESTITEM
    
    3) From [Select Action]-[Add Items to Storeroom],
    add the item to the storeroom [CENTRAL].
    
    4) On [Add Items to Storeroom] window,
    specify the following values and click OK.
    
    Issue Unit : EACH
    Current Balance : 1
    
    5) Click [Change Status] icon and specify
    the following values on [Change Status] window.
    
    New Status : Active
    Roll New Status to Organizations
    and Inventory : Checked
    
    6) From [Inventory] application, open "TESTITEM" and
    confirm the following values.
    
    Current Balance : 1
    Hard Reserved Quantity Not Staged : 0
    Quantity Available : 1
    
    7) From [Work Order Tracking],
    create a new Work Order with the
    following values.
    
    WONUM : TESTWO
    Description : Test Work Order
    
    8) On [Plans] tab, open [Materials] sub tab and click
    [Select Materials] button to select the Item TESTITEM.
    Then specify the following values.
    
    Quantity : 1
    Storeroom : CENTRAL
    Reservation Type : Automatic
    
    9) Change the status for
    this Work Order to [Approved].
    
    10) From [Inventory] application,
    open the item [TESTITEM] and confirm the
    following values.
    
    Current Balance :1
    Hard Reserved Quantity Not Staged : 1
    Quantity Available : 0
    
    11) From [Object Structures] application,
    open [MXINVISSUE] object structure and check
    [Support Flat Structure?].
    
    12) From [External Systems] application,
    open the external system [EXTSYS1] and select
    [MXINVISSUEInterface] on [Enterprise Services] tab.
    
    13) Click [Data Import] button
    and select the following values.
    
    Flat File : checked
    Import Preview? : checked
    Specify File : TESTWO.TXT
    
    Note the content of TESTWO.TXT is as below.
    
    EXTSYS1,MXINVISSUEInterface,Add,JA
    WONUM,ITEMNUM,LINETYPE,STORELOC,SITEID,QUANTITY,
    UNITCOST,ISSUETYPE,GLDEBITACCT,GLCREDITACCT,SENDERSYSID,
    TESTWO,TESTITEM,ITEM,CENTRAL,BEDFORD,1,0,ISSUE,6600-800-800,
    6210-300-200,MX
    
    14) Then the following error is shown.
    
    BMXAA5598E - Processing of an inbound transaction failed.
    The processing exception is identified in document 1.
    BMXAA1891E - The available balance will become negative as a
    result of this transaction.
    
    EXPECTED RESULTS:
    Actually the quantity available for the item
    TESTITEM is 0 because it is reserved by the
    work order TESTWO. Since TESTWO is specified
    for WONUM in the import file, this MATUSETRANS
    record should be imported without any errors.
    
    PRODUCT VERSION:
    Maximo Asset Management 7.6.0.9
    

Local fix

  • The error does not happen if you click [Select Reserved Items]
    from [Issues and Transfers] and select the item reserved by the
    Work Order or if you create a new Inventory Usage record from
    [Inventory Usage] and click [Select Reserved Items] in [Usage
    Lines] section and then select the item reserved by the Work
    Order.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * MAXIMO                                                       *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * BMXAA1891E IS THROWN WHEN ISSUING A RESERVED MATERIAL WITH   *
    * THE ASSOCIATIED WONUM THROUGH MIF USING THE MXINVISSUE OBJ   *
    * STRUCTURE                                                    *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is contained in the following maintenance
    package: release\fix pack for Release 7.6.1.3 Product
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ32052

  • Reported component name

    WORK ORDERS

  • Reported component ID

    5724R46WO

  • Reported release

    760

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-04-12

  • Closed date

    2021-07-27

  • Last modified date

    2021-07-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WORK ORDERS

  • Fixed component ID

    5724R46WO

Applicable component levels

[{"Line of Business":{"code":"LOB59","label":"Sustainability Software"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"Maximo Asset Management"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"760"}]

Document Information

Modified date:
28 July 2021