IBM Support

IJ31135: BMXAA4196E - ATTRIBUTE SITE MUST BE SET BEFORE CONTENT UID CAN BE SET , WHEN YOU OPEN DRILLDOWN

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • ERROR DESCRIPTION:
    BMXAA4196E - Attribute Site must be set before Content UID can
    be set , when you open DrillDown
    
    PROBLEM:
    After enabling this extended drill-down (System properties
    mxe.webclient.extendedDrillDown), when the user unchecked the
    "Use Default insert site as a display filter" checkbox on their
    profile (Default Information Dialog box), clicking on the open
    drilldown from the workorder application is causing this error
    as below :
    
    BMXAA4196E - Attribute Site must be set before Content UID can
    be set.
    
    The exception log is as follow
    10 Feb 2021 06:27:21:614 [DEBUG] [mx01us281] [] Generated
    exception
    psdi.util.MXApplicationException: BMXAA4196E - Attribute Site
    must be set
    before Content UID can be set.
     at psdi.mbo.MAXTableDomain.validate(MAXTableDomain.java:149)
     at
    psdi.app.common.virtual.FldExtDrillDownSystemId.validate(FldExtD
    rillDownSystemId.java:22)
     at psdi.mbo.MboValue.validate(MboValue.java:1732)
     at psdi.mbo.MboValue.setValue(MboValue.java:914)
     at psdi.mbo.MboValue._setValue(MboValue.java:1279)
     at psdi.mbo.MboValue.setValue(MboValue.java:1175)
     at psdi.mbo.Mbo.setValue(Mbo.java:2414)
     at
    psdi.app.common.virtual.ExtDrillDown.add(ExtDrillDown.java:48)
    
    STEPS TO REPLICATE :
    0) Enable the mxe.webclient.extendedDrillDown properties as
    true in System Properties app
    1) Go to the Workorder Tracking application
    2) Click on the Profile link, and select Default Information
    3) Select a Default insert Site
    4) Remove the flag for: Use Default Insert Site as a Display
    Filter?
    5) Click OK
    6) Back in the Workorder Tracking application  - hit ENTER to
    return a list of records
    7) For any record, go to the detail button of a Location field
    and click "Open Drilldown"
    8) You will get an Error Message:
    BMXAA4196E - Attribute Site must be set before Content UID can
    be set.
    
    CURRENT ERRONEOUS RESULT:
    BMXAA4196E - Attribute Site must be set before Content UID can
    be set , appears when you open DrillDown with the new drilldown
    feature.
    
    EXPECTED RESULT:
    Be able to open the new drilldown without any errors
    
    ENVIRONMENT (SYSTEM INFO):
    App Server :         IBM WebSphere Application Server 9.0.0.7
    Tivolis process automation engine 7.6.1.2 Build 20200715-0100
    DB Build V7612-284
    IBM Maximo Asset Management Work Centers 7.6.0.4 Build
    20200715-0100 DB Build V7604-119
    IBM Tpae Integration Framework 7.6.1.2 Build 20200615-2330 DB
    Build V7612-11
    IBM Maximo for Service Providers 7.6.3.4 Build 20200803-2349 DB
    Build V7634-10
    IBM Maximo Asset Management 7.6.1.2 Build 20200715-0100 DB
    Build V7611-01
    IoT Connection Utility 7.6.0.3 Build 20200701-1409 DB Build
    V7603-32
    

Local fix

  • NA
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * MAXIMO                                                       *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * ATTRIBUTE SITE MUST BE SET BEFORE CONTENT UID CAN BE SET ,   *
    * WHEN YOU OPEN DRILLDOWN                                      *
    ****************************************************************
    

Problem conclusion

  • Code correction in ExtDrilldown.java
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ31135

  • Reported component name

    SYSTEM CONFIG

  • Reported component ID

    5724R46S1

  • Reported release

    761

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-03-02

  • Closed date

    2021-10-18

  • Last modified date

    2021-10-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    SYSTEM CONFIG

  • Fixed component ID

    5724R46S1

Applicable component levels

[{"Line of Business":{"code":"LOB59","label":"Sustainability Software"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"Maximo Asset Management"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761"}]

Document Information

Modified date:
19 October 2021